Descargar Imprimir esta página

StetSom Bravo Full 2000 Manual De Usuario página 5

Publicidad

Idiomas disponibles

Idiomas disponibles

Indicators LED
Smart protection system
When the protection system detects a failure, the amplifier will turn off and
the PROT LED will blink. For each type of failure, the LED will flash a certain
number of times indicating the cause, as shown in the table below:
Diagnostic: Short circuit or output overload.
Solution: Check that the speaker cables are well insulated and that the output
blink
1x
impedance does not exceed that supported by the amplifier.
Diagnostic: Excessive temperature. When the amplifier reaches approximately
194°F, audio is stopped and the coolers run at maximum speed to speed up the
cooling process of the internal components.
blink
Solution: Check if the amplifier is in a ventilated place or if the coolers are not
2x
obstructed. Keep the amplifier turned on for a few minutes for the coolers to
assist in the cooling process.
Diagnostic: Supply voltage less than 9V.
blink
Solution: Check voltage of battery or power supply.
3x
Diagnostic: Supply voltage greater than 16V.
blink
Solution: Check voltage of battery or power supply.
4x
POWER (blue LED): Indicates amplifier operation
when it is on.
PROT (top red LED): Indicates that the amplifier
encountered malfunctions and entered protection
mode, forcing it to shut down. Verify in the protection
table below the possible problem and turn on the
amplifier again.
CLIP (lower red LED): Indicates signal distortion at the
amplifier output.
5

Publicidad

loading