Cleaning And Maintenance; Technical Specifications - HQ-Power VDL1500ST Manual Del Usuario

Estroboscopio 1500w
Ocultar thumbs Ver también para VDL1500ST:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

6. Use
Refer to the illustrations on page 2 of this manual.
Insert the plug into the mains outlet.
Set the mode switch [4] to I (AUTO-RUN) to use the stroboscope in manual mode: light intensity is set by
control [6], strobe speed is set by control [7].
Set the mode switch [4] to II (SOUND) to use the stroboscope in sound controlled mode: sound sensitivity is
set by control [5]; light intensity is set by control [6].
Using a remote controller (not incl., e.g. VDL1500RCN)
Plug the connector of the remote control cable (not incl.) into the input jack [8] of the VDL1500ST.
Set the mode switch [4] to II (SOUND) and rotate the sound sensitivity control [5] fully anticlockwise to
avoid that the VDL1500ST reacts to sound.
Switch on the remote controller and control the strobe speed using the knob on the remote.
Connecting multiple VDL1500STs
If you want to connect multiple VDL1500STs, plug one side of the connection cable with 6.35mm TRS
stereo connectors (not incl.) in the output jack [10] of the master [A] and plug the other end into the
input jack [8] of the slave device [B].
Note: when using a remote controller in this setting, it must be connected to the master device.
NOTE: It is possible that your stroboscope is not working. In this case, open the cover at the front and check the
connections. The insulation may be too deep in the connector. Loosen the screws and pull the wires out a
few millimetres to make a good connection. Fasten the screws again.
To switch off the device, set the mode switch [4] to the middle position (O).

7. Cleaning and maintenance

All screws should be tightened and free of corrosion.
The housing, visible parts, mounting supports and the installation location (e.g. ceiling, suspension, trussing)
should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not
change the location of the connections.
The electric power supply cables must not show any damage. Have a qualified technician maintain the
device.
Disconnect the device from the mains prior to maintenance activities.
Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
There are no user-serviceable parts.
Contact your dealer for spare parts if necessary.

8. Technical Specifications

power supply
power consumption
lamp
fuse
dimensions
Max. Ambient Temperature
weight
Use this device with original accessories only. Velleman nv cannot be held responsible in the event of
damage or injury resulted from (incorrect) use of this device. For more info concerning this product
and the latest version of this manual, please visit our website www.hqpower.eu. The information in
this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved.
No part of this manual or may be copied, reproduced, translated or reduced to any electronic medium or
otherwise without the prior written consent of the copyright holder.
22.11.2011
VDL1500ST
max. 230Vac / 50Hz
max. 1600W
1 x 1500W lamp (order code LAMP1500ST)
F 20A, 250VAC (6.35 x 32mm) (order code 6FF20N)
530 x 200 x 117mm
45°C
4.5kg
5
Rev. 02
©Velleman nv

Publicidad

Tabla de contenido
loading

Tabla de contenido