3. Specifications
3.7 Operating conditions
Ingress protection (per IEC 60529)
IP 65
GB
Temperatures
Medium:
■
- Measuring range < 100 bar:
- Measuring range ≥ 100 bar:
Ambient:
■
Storage:
■
3.8 Materials
Wetted parts
Process connection:
■
Sensor element ≤ 50 bar:
■
Sensor element > 100 bar: XM-13 (stainless steel 1.4534)
■
Non-wetted parts
Case:
■
Front foil and membrane:
■
For special model numbers, e.g. DG-10000, please note the specifications stated on the delivery note.
For further specifications see WIKA data sheet PE 81.66 and the order documentation.
12
-30 ... +85 °C
-30 ... +100 °C
-10 ... +60 °C
-20 ... +70 °C
Stainless steel 1.4571
Ceramic Al2O3 96 %
NBR (option: EPDM)
Stainless steel 1.4301
Polyester
WIKA operating instructions digital pressure gauge, model DG-10