reaches its opening limit position; the second command closes the gate;
if another command is transmitted before motor time has elapsed or
before one of the limit stops has been reached, the control unit stops the
movement. Another command causes the gate to start moving again in the
opposite direction.
Step-by-step 1 operations:
When either the remote or the low voltage control pushbuttons are used to
control the gate, operation is as follows:
the first command opens the gate until motor time or until the gate
reaches its opening limit position; the second command closes the gate;
if another command is transmitted before motor time has elapsed or
before one of the limit stops has been reached, the control unit stops the
movement during both opening and closing. Another command causes the
gate to start moving again in the opposite direction.
AUTOMATIC CLOSING:
The control unit can be set up to close the gate automatically without
sending any additional commands.
The selection of this type of operation is described in Pause time
programming mode.
PEDESTRIAN OPENING:
By means of the radio remote control (CODE P. LED on) the control unit
makes it possible to drive the Operator for a programmable time, typically
to allow pedestrian access.
EMERGENCY STOP INPUT:
The control unit allows the connection of an emergency stop pushbutton
(NC). Pressing this pushbutton irrespective of the current operating mode
of the control unit will cause immediate stopping of the gate movement. An
additional gate movement command will be valid provided the emergency
stop input is deactivated and, in any case, the control unit will execute the
gate opening cycle with 5 seconds preflashing.
IMPORTANT: Jumper this input if it is not to be used.
PHOTOCELLS:
Photocells can be powered by and connected to the control unit in
accordance with directive EN 12453. Tripping of the photocells during
opening is disregarded, while during closing it causes reversal of the
direction of movement.
To allow operation in compliance with EN 13849-1 Category 2 a photocell
test is performed before each movement. The control unit enables the
movement only if the test is passed; if it is not, the control unit inhibits
all movements and an alarm condition is signalled by blinking of all the
programming LEDs on transmission of any command.
OPERATOR FORCE ADJUSTMENT (FORCE):
The electronic control unit is equipped with a "FORCE" trimmer for
adjustment of the Force delivered by the operators, completely managed
by the microprocessor. Adjustment can be performed in a range of between
50% and 100% of maximum force. Initial starting torque can be set for each
movement by feeding the operator at full power for 2 seconds, even if
operator force control is enabled. Note: initial starting torque is disabled
automatically if the Soft Start function is enabled.
IMPORTANT: If the "FORCE" trimmer is adjusted, the self-learning
procedure must be repeated because the movement and deceleration
times may change.
DECELERATION (SLOW):
The operators deceleration function is used on gates to prevent the moving
leaves from slamming at speed into the limit stops at the end of the opening
and closing strokes. During Motor Time programming (see Main menu)
the control unit allows programming of deceleration in the required points
(immediately before full opening and full closing); in addition, using the
"SLOW" trimmer the force intensity can be adjusted during the deceleration
phase.
OPERATION WITH TIMER:
The control unit allows a timer to be connected in place of the open – close
pushbutton. E.g.: at 08.00 am the timer closes the contact and the control
unit commands an opening movement; at 06.00 pm the timer opens the
contact and the control unit commands a closing movement. From 08.00
am - 06.00 pm at the end of the opening cycle the control unit disables the
flashing light, automatic closing and the remotes.
PROGRAMMING:
SELECT key: selects the type of function to store; the selection is indicated
by blinking of the LED.
Press the key repeatedly to go to the required function. The selection
remains active for 10 seconds shown by blinking of the LED; when this
interval elapses, the control unit returns to the original state.
SET key: programs the information in accordance with the function type
preselected with the SEL key.
IMPORTANT: The SET key function can be replaced by the remote if
programmed beforehand (CODE LED on).
Programming enabled only when safety devices are not active.
MAIN MENU
The control unit is factory set to allow the selection of several important
functions.
L1
DIR
L2
STEP BY STEP
Step-by-Step
L3
CODE TX
Code entered
L4
CONDO
L5
MOTOR TIME
Programmed time
L6
PAUSE TIME
With automatic closing
L7
AUTO PROGRAM
LEV
MENU
1. OPENING DIRECTION (DIR):
In the default configuration the control unit is set with "OPEN TO RIGHT"
logic (seen from the operator side, with operator installed to the right of
the sliding leaf); if the "OPEN TO LEFT" logic must be enabled (seen from
operator side, with operator installed to the left of the sliding leaf), proceed
as follows: use the SELECT key to select the blinking OPEN DIRECTION
LED and then press the SET key: the OPEN DIRECTION LED becomes
steady on and programming will be completed. Repeat the procedure if you
wish to restore the previous configuration.
2. STEP-BY-STEP:
In the default configuration the control unit is set with "Automatic" operating
logic enabled (LED n2 off); if the "Step-by-Step" operating logic is required
(LED n2 on), proceed as follows; use the SELECT key to select blinking
LED n2 and then press the SET key: LED n2 becomes steady on and
programming will be completed.
If the "Step-by-Step 1" operating logic is required, repeat the operation
above described, by pressing the SEL key twice instead only one (to obtain
the quick blinking of LED .
Repeat the procedure if you wish to restore the previous configuration.
3. TX CODE: (REMOTE CONTROL CODE)
Up to 120 remotes with different codes, either of the fixed or the rolling
code type can be saved on the control unit.
Programming:
Programming of the transmission code is performed as follows: use the
SELECT key to select blinking LED L3. Press SET once; the LED will change
its blinking mode (longer 1 0 1 0) to show that the first level is being saved.
On sending the selected code with the required remote, the CODE LED
will remain steady on to indicate that programming has been completed.
To save the code for pedestrian opening / single leaf proceed as follows:
use the SELECT key to select blinking CODE LED L3. Press SET twice
consecutively; the LED will change its blinking mode (1 1 0 1 1 0) to show
that the pedestrian code is being saved. On sending the selected code
with the required remote, CODE LED L3 will remain steady on to indicate
that programming has been completed. If all 120 codes have been saved,
repeating the programming operation will cause all the programming LEDs
to start blinking to signal that no further codes can be saved.
COMUNELLO ®Copyright 2014 - All right reserved
Left Open
Right Open
Automatic
No code
ON
OFF
30 sec.
Without automatic closing
ON
OFF
ON