7.1. Faults Display
Problem
RTC
GB
CABINET
PROBE
EVAPORATOR
PROBE
CONDENSER
PROBE
HUMIDITY
PROBE
POWER
FAILURE
Causes
RTC Alarm
Malfunctioning of the
internal clock.
Time not set
Cabinet Probe Alarm
Cabinet probe
damaged
Evaporator Probe
Alarm
Evaporator probe
damaged
Condenser Probe
Alarm
Condenser probe
damaged
Humidity Probe
Alarm
Humidity probe
damaged.
Power failure alarm
Effects
The buzzer is active. The buzzer
can be silenced pressing any key.
Any running cycle will be stopped
and all outputs disabled..
The buzzer is active. The buzzer
can be silenced pressing any key.
Any running cycle will be stopped
and all outputs disabled.
.
The buzzer is active. The buzzer
can be silenced pressing any key.
The defrostings end time-out (see
parameter d3)
The buzzer is active. The buzzer
can be silenced pressing any key.
The condenser fan will runs in
parallel to the compressor.
The buzzer is active. The buzzer
can be silenced pressing any key.
Any cycle that involves the use of
the humidity probe will be
terminated.
18
Solutions
Set the date ant the current
time.
Check the connection and
the integrity of the cabinet
probe. If necessary replace
it.
Contact the after-
sales service..
Alla scomparsa dell'errore il
ciclo riprende.
Check the connection and
the integrity of the
evaporator probe. If
necessary replace it.
Contact the after-
sales service..
Check the connection and
the integrity of the cell
probe. If necessary replace
it.
Contact the after-
sales service..
Check the connection and
the integrity of the humidity
probe. If necessary replace
it.
Contact the after-
sales service..
Verify the electrical power
supply.