Date display format
For specifying the format in which the date is displayed
Setting range
Factory setting
Daylight saving time
Activating/deactivating the automatic adjustment for daylight saving time
IMPORTANT! Only use the function for automatic daylight savings adjustment when
there are no LAN or WLAN-compatible system components in a Fronius Solar Net Ring
(e.g., Fronius Datalogger Web, Fronius Datamanager or Fronius Hybridmanager).
Setting range
Factory setting
IMPORTANT! The time and date must be set correctly for day and year values to be dis-
played properly.
Display Settings
Setting range
Language
Setting the display language
Setting range
Night Mode
DATCOM night mode; controls DATCOM and display operation at night or when there is
insufficient DC voltage available
Setting range
Factory setting
Contrast
set contrast on the display
Setting range
Factory setting
mm/dd/yyyy / dd.mm.yy
depends on the country setup
on/off
on
Language / Night mode / Contrast / Illumination
German, English, French, Dutch, Italian, Spanish, Czech, Slo-
vak, etc.
AUTO / ON / OFF
OFF
AUTO:
DATCOM operation is constant as long as a Datalogger is connected to an
active, uninterrupted Solar Net.
The display is dark during the night and can be activated by pressing any
key.
ON:
DATCOM operation is constant. The inverter provides 12 V constantly to
supply Solar Net with power. The display is always active.
IMPORTANT! The power consumption of the inverter is increased at night
to approximately 7 W when the DATCOM night mode is ON or on AUTO and
Solar Net components are connected.
OFF:
No DATCOM operation at night, the inverter requires no AC power to supply
Solar Net.
The display is deactivated at night; the Fronius Datamanager is not avail-
able.
0–10
5
31