Maintenance and care
Air intake
Cleaning silencer
Check fuel system
Check spark plug
Lubricating flexible shaft
Keep dirt away from engine and air intake grid.
Carbon deposits in silencer (A) will cause a drop in engine out-
put and overheating. Clean deposits from silencer.
IMPORTANT
Do not remove the silencer cover. If necessary, Please consult
your dealer.
Check before every use.
After refuelling, make sure fuel does not leak or exude from
around fuel pipe (A), fuel grommet (B) or fuel tank cap (C).
In case of fuel leakage or exudation, there is a danger of fire.
Stop using the machine immediately and request your dealer
to inspect or replace.
1.
Check plug gap. Correct gap is 0.6 mm to 0.7 mm.
2.
Inspect electrode for wear.
3.
Inspect insulator for oil or other deposits.
4.
If the electrodes or terminals are worn, or if there are cracks
in the ceramics, replace them with new parts.
5.
Tighten to 15 N·m - 17 N·m (150kgf·cm to 170 kgf·cm).
The spark test (for checking whether the spark plug is spark-
ing) must be carried out by your dealer.
All the surface of the flexible shaft should always be properly
greased.
At the time of delivery from the plant, this is greased, so evenly
grease all the surface of the flexible shaft approximately 10 mL
in every 18 hours.
1.
Draw out the flexible shaft assembly from the angle trans-
mission.
22