7
1.
If the pruners stop working during long term use and you hear 4 fast beeps, this is an indica-
tion of undervoltage protection which means the battery is depleted. Please charge as soon
as possible.
2.
In order to conserve the use of battery power and ensure that the pruning shears have the
longest service life, do not overload the device and avoid cutting branches with a diameter
larger than 40 mm.
3.
During the shearing process, if the shearing knife encounters a branch that cannot be cut off,
then release the trigger to reopen the blades, after which the next normal shear session can
be carried out.
The blades of the pruner should not be moved around while cutting, so as not to
damage the blades. Never move the pruner side to side when wedged.
Reading the LED display
To determine the shears' battery charge level and keep the count of the performed cuts
(Table 1), the shears are equipped with a LED display.
On the LED display it is also possible to read other signals about maintenance and faults
(Table 2).
150
Art. 315
Pruning shears Titania E-40 TP
Usage
Art. 315
Pruning shears Titania E-40 TP
Usage
Display
(Table 1)
Codice
Descrizione
1
Anti-cut system active
2
Software current error
3
PCB damage
5
Overcurrent
6
Geared motor jammed
7
Motor out of phase
(Table 2)
For further information about the product, please contact info@stockergarden.com
7
Description
The battery charge level is displayed with a number
between 0 and 100.
The total number of performed cuts is displayed within
10 seconds from the swtich-on. Subsequently the dis-
play shows the amount of cuts from the switch-on.
Soluzione
1. Do not touch the blades or the branch
2. Deactivate the anti-cut system
Replace the PCB
Replace the PCB
1. Replace the geared motor
2. Replace the PCB
1. After removing the motor, activate the trigger. If the
motor still cannot rotate, replace the motor
2. When removing the blade, if the pin is difficult to
knock down, the pin is deformed and stuck. Replace
the blade.
3. After removing the motor and blade, if the adaptor
cannot be turned easily, the adaptor is stuck. Replace
the geared motor.
1. Ensure that the motor is correctly connected to
the PCB
2. Replace the geared motor
151