Use - SATA jet 5000 B Instrucciones De Servicio

Ocultar thumbs Ver también para jet 5000 B:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 133
Operating instructions SATAjet 5000 B RP/HVLP (DIGITAL)
EN
• Use of solvents and cleaning agents based on halogenised hydrocar-
bons! Chemical reactions which may occur when using these sub-
stances could be explosive!
6.4.2
Additional notes concerning the electronic
pressure gauge
The electronic pressure gauge has passed a design examination. It has
been developed, constructed and manufactured in accordance with the
EU directive 94/9 EU. It has been classified according to Ex ia IICT4 Ga
or Ex ia IICT4 Gb. It may be used and stored in the explosive zones 1 and
2 up to 60°C ambient temperature. Inspection authority: KEMA 05 ATEX
1090 X.
The following applications and operations lead to the loss of
the explosion protection and are, therefore, prohibited:
• Battery exchange in explosive areas!
• Removal of the front cover of the pressure display!
• Installation of a battery other than the CR 1632 Renata!
When exchanging the battery, it is recommended to also replace the
sealing of the battery compartment!
7.

Use

• Use only solvent-resistant, antistatic, undamaged and technically flaw-
less compressed air hoses with a permanent pressure resistance of
minimum 10 bar, e.g. Art. No. 53090!
The following requirements must be fulfilled:
120
Warning! Risk of explosion!
Warning! Risk of explosion!
Warning! Risk of explosion!