G
IMPORTANT SAFETY INSTRUCTIONS FOR THE INSTALLATION
B
ATTENTION - FOR THE SAFETY OF PEOPLE IT IS IMPORTANT TO FOLLOW ALL THE INSTRUCTIONS
KEEP THESE INSTRUCTIONS WITH CARE
1° - If it is not forecast in the electric gearcase, install a switch of magneto thermic type
upstream, (omni polar with minimum opening of the contacts of 3 mm) with a check of
conformity to the international standards. Such device must be protected against the
accidental lockup (for example by installing inside a locked board).
2° - For the section and the type of the cables RIB advices to use a cable of H05RN-F type
with 1,5 sqmm minimum section and, however, to keep to the IEC 364 and installation
standards in force in your country.
3° - Positioning of a possible couple of photoelectric cells: the radius of the photoelectric cells
must be at a height of no more than 70 cm from the ground and at a distance not superior
to 20 cm from the motion plane of the door. Their correct working must be verified at the
end of the installation in accordance with the EN 16005
4° - To fulfill the limits set by EN 16005, and in case the peak force exceeds the normative
limit of 400 N it is necessary to have recourse to the active presence survey on the
whole height of the door (up to max 2,5 m) - The sensors, in this case, must be applied in
accordance with the EN 16005.
N.B.: The earthing of the system is obligatory.
The data described in this handbook are purely a guide.
RIB reserves the right to change them in any moment.
Carry out the system in the respect of the standards and laws in force.
IMPORTANT SAFETY INSTRUCTIONS FOR THE INSTALLATION
ATTENTION - THE INCORRECT INSTALLATION CAN CAUSE SERIOUS DAMAGES
FOLLOW ALL INSTALLATION INSTRUCTIONS
1° - This handbook is exclusively addressed to the specialized personnel who knows the
constructive criteria and the protection devices against accidents for motorized gates,
doors and main doors (follow the standards and the laws in force).
2° - The installer will have to issue a handbook to the final user in accordance with the 12635.
3° - Before proceeding with the installation, the installer must forecast the risks analysis of
the final automatized closing and the safety of the identified dangerous points (Following
the standard EN 16005).
4° - Before installing the motion motor, the installer must verify that the gate is in good
mechanical conditions and that it adequately opens and closes.
5° - The installer must install the member for the manual release at a height inferior to 1,8 m.
6° - The installer will have to remove possible impediments to the motorized motion of the
gate (eg. door bolts, sliding bolts, door locks etc.)
7° - The installer will permanently have to put the tags warning against the deflection on a
very visible point or near possible fixed controls.
8° - The wiring harness of the different electric components external to the operator (for
example photoelectric cells, flashlights etc.) must be carried out according to the EN
16005.
9° - The possible assembly of a keyboard for the manual control of the movement must be
done by positioning the keyboard so that the person operating it does not find himself
in a dangerous position; moreover, the risk of accidental activation of the buttons must
be reduced.
10° - Keep the automatism controls (push-button panel, remote control etc.) out of the
children way. Command device for operating the motor (a switch manually closed)
should be placed in area visible from the guided site and far from moving parts. It should
be placed at least at 1,5 m height.
11° - this appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge
if they have been given supervision or instruction concerning use of the appliance in a
safe way and understand the hazards involved
12° - children shall not play with the appliance
13° - cleaning and user maintenance shall not be made by children without supervision
14° - do not allow children to play with fixed controls. Keep remote controls away from
children
15° - Fixed command devices should be installed in a well visible way.
16° - Before carrying out any installation, regulation or maintenance operation of the system,
take off the voltage by operating on the special magneto thermic switch connected
upstream.
17° - At the end of the installation, the installer will have to make sure that the parts of the
door do not encumber streets or public sidewalks.
THE RIB COMPANY DOES NOT ACCEPT ANY RESPONSIBILITY for possible damages caused by
the non observance during the installation of the safety standards and of the laws in force
at present.
2