Descargar Imprimir esta página

Ribind UP 2.0 Manual De Instrucciones página 43

Publicidad

Idiomas disponibles

Idiomas disponibles

LOW ENERGY ADJUSTMENT
For Low Energy settings, execute the following operations:
- adjust PUSH force ≤ 5;
- Adjust the VOP opening speed to open the door (from 0° TO 80°) In the times indicated in the table;
- Adjust the VCL closure speed to close the door (from 90° TO 10°) In the times indicated in the table;
Speed settings for automated leaf doors with low voltage
The table displays the minimum opening time (in seconds)
Length of door
50 kg
0,75 m
3,0 s
0,85 m
3,0 s
1,00 m
3,5 s
1,20 m
4,0 s
0°÷80° ≥ 3 s
(ver tabla)
Weight of door
60 kg
70 kg
3,0 s
3,0 s
3,0 s
3,5 s
3,5 s
4,0 s
4,5 s
4,5 s
15
80 kg
90 kg
3,0 s
3,5 s
3,5 s
4,0 s
4,0 s
4,5 s
5,0 s
5,5 s
G
B
90°÷10° ≥ 3
(ver tabla)

Publicidad