▪ The supply voltage at the reader's connector should be between +7 Vdc and +28 Vdc.
▪ Recommended distance between two readers: parallel plane: 11.8 in – same plane: 15.8 in – perpendicular plane: 9.8 in.
▪ Use a ferrite (two-way) for the cable (power supply and data).
For data signals, 10k pull-up resistors are connected internally to Vin (power supply voltage) for optimal wiring distances.
Available Baud rate
Factory Baud rate
Mode
Number of bits
Transfer mode
Stop bit
RS485
RT: 120 Ω end-of-line resistor supplied.
Depending on the version of the SE2 electronic board, the readers are fitted directly or not with pull-up / pull-down resistors on the electronic
board. The board version can be found on the label:
Earlier versions of electronic board and LEGIC electronic board (SE2L) require the wiring of resistors R1 and R2 (1.5 kΩ resistors supplied) to
use the extended features of the RS485 Bus: FAIL-SAFE (see RS485-AN-960).
STid declares that the readers are compliant to the essential requirements of the Directive R&TTE 1999/5/CE. A copy of our declaration is
available upon request to qualite@stid.com.
Product Safety Data Sheet according to EU REACH Regulation
INERIS 13ATEX0021X – GUB Enclosure Certificate
INERIS 09ATEX028X –Cable gland Certificate
A copy of the certificates is available in the Customer Area on the STid.com website
ATEX & IECEX reader
Installation procedure
9600, 19200, 38400, 57600, 115200 bauds
ATX/ATX2 R & S: 9600; ATX/ATX2 W: 38400 (SSCP
Default broadcast address 00h
© STid - 20 PA des Pradeaux FR13850 Gréasque – NI1104X05 - Page 5 sur 15 - Ed. 25/05/2023
Lecteur ATEX & IECEX
Notice d'installation
Precautions for installation
Example: reference 74271222 WURTH ELEKTRONIK
TTL pull-ups
RS232/RS485 communication
), 9600 (OSDP
®
Asynchronous
8
LSB first
1
Bus architecture (RS485)
pull-up / pull-down on electronic board
Variant
0, 1, 2, 3 ou 4
5
Declaration of compliance