Descargar Imprimir esta página

Homelite UT9C5000D Manual Del Operador página 19

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNING:
When servicing, use only identical replacement parts.
Use of any other parts could create a hazard or cause
product damage.
WARNING:
Always wear eye protection with side shields marked to
comply with ANSI Z87.1. Failure to do so could result in
objects being thrown into your eyes, resulting in possible
serious injury.
Only the parts shown on the parts list are intended to be
repaired or replaced by the customer. All other parts should
be replaced at an authorized service center.
GENERAL MAINTENANCE
Before each use, inspect the entire product for damaged,
missing, or loose parts such as screws, nuts, bolts, caps, etc.
Tighten securely all fasteners and caps and do not operate
this product until all missing or damaged parts are replaced.
Please call 1-800-242-4672 or contact an authorized service
center for assistance.
Keep the generator in a clean and dry environment where it
is not exposed to dust, dirt, moisture, or corrosive vapors.
Do not allow the cooling air slots in the generator to become
clogged with foreign material such as leaves, etc.
Do not use a garden hose to clean the generator. Water en-
tering the fuel system or other internal parts of the unit can
cause problems that will decrease the life of the generator.
To clean the unit:
 Use a soft bristle brush and/or vacuum cleaner to loosen
and remove dirt and debris.
 Clean air vents with low pressure air that does not exceed
25 psi.
 Wipe the exterior surfaces of the generator with a damp
cloth.
MAINTENANCE
CHECKING/CLEANING AIR FILTER
See Figure 12.
For proper performance and long life, keep air filter clean.
 Open the clasp on the air filter cover. Remove cover and
set aside.
 Remove the filter element.
 Remove the filter gasket. Wipe with a clean cloth and
replace in the air filter unit.
 If the filter element is dirty, clean with warm, soapy water.
Rinse and let dry.
 Apply a light coat of engine lubricant to the element, then
squeeze it out.
 Replace the element in the air filter unit.
 Replace the air filter cover and close the clasp to secure.
NOTE: Do not run the generator without the air filter or
gasket. Rapid engine wear will result.
CHANGING ENGINE LUBRICANT
See Figure 13.
 Remove the oil cap/dipstick.
 Place a container underneath the oil drain plug to collect
used lubricant as it drains.
 Unscrew the oil drain plug and remove.
 Allow lubricant to drain completely.
 Reinstall the oil drain plug and tighten securely.
 Refill with lubricant following the instructions in the
Checking/Adding Lubricant section.
 Reinstall the oil cap/dipstick.
NOTE: Used lubricant should be disposed of at an approved
disposal site. See your local oil retailer for more information.
Page 15 — English

Publicidad

loading