4. SAFETY
The safety of the board are managed via DIP 3 and 4:
DIP 3 SAFETY LOGIC
When an obstacle is detected during the way down the movement is reversed until the opening
OFF
limit switch; It has no effect on the way up.
When an obstacle is detected during the way down the opening movement is inverted for 2
ON
seconds and then it stops. When an obstacle is detected during the way up the movement is
immediately stopped.
DIP 4 TYPE OF SAFETY SELECTION
OFF
Security input for normally closed contact.
Security input for optoelectronic bar with digital signal. To be connected as follows: Mass in
ON
terminal 3, + 12V DC in terminal 9, digital signal in terminal 10.
5. OPTOELECTRONIC BAR AND/OR PHOTOCELL
To connect the optoelectronic bar QCSE and the photocell,
the latter must be connected in series to the digital signal of
the bar as shown (DIP 4 in ON).
12
11
10
6. INTEGRATED COURTESY LIGHT
The courtesy lamp contact will activate ifself, after an opening input, once the
door is completely closed and the operation time over.
The contact of the courtesy light has two working modes:
• switch on in case of opening and authomatical switch off after 3 minutes
• switch on for two seconds while opening (useful to operate a lighting system).
In order to switch from one mode to the other, please move the dip 2 on ON and then on OFF for at least
three times (you should move consecutively from OFF to ON within 2 seconds, otherwise the number of
movements will be reset to zero). The leds will inform you about the selected mode:
• Activation of mode 3 minutes: green led ON, red led flashing slowly for 3 seconds
• Activation of mode 2 seconds: green led ON, red led flashing quickly for 3 seconds
In case the courtesy light is matched with a radio code, the transmission of the command will cause the
activation of the relé for 3 minutes or 2 seconds according to the control unit programming. In case of tran-
smission of the command with active relé, it will be deactivated.
14
9
8
7
6
5
4
3
GRD - White
+12Vcc - Brown
SIGNAL - Green
To connect the the photocell,
the latter must be connected as
shown (DIP 4 in OFF).
12
11
20
21
230 V
50-60 Hz
10
9
13
14