Gas adjustment
■ Take precautions on the operations and adjustments to be carried
out when converting from one gas to another.
■ All work must be carried out by a qualified technician.
■ Before you begin, turn off the gas and electricity supply to the
appliance.
1
Change the injector of the burners.
2
Adjustment of minimum level of the flame.
■ Do not dismantle the tap shape:
in the event of a malfunction,
change the whole tap.
■ Before placing the burners back
on the top place, make sure that
the injector is not blocked.
■ A full operational test and a test
for possible leakages must be
carried out after gas conversion.
(such as soap water or gas
detector)
Remove the pan support, Burner lid and Flame
spreader.
Unscrew the injector using a 7mm box spanner and
replace it with the stipulated injector for new gas
supply. Carefully reassemble the all components.
After injectors are replaced, it is advisable to
strongly tighten the injector in place.
Injector
Turn the taps down to minimum.
Remove the knob from the tap and place a small
Control handle
bladed screwdriver in the centre of the tap shaft.
The correct adjustment is obtained when the
flame has a length of about 3 - 4 mm.
Tap
- For butane / propane gas, the adjusting screw must
Sealing ring
be tightly screwed in.
- Refit the control knob.
- Make sure that the flame does not go out by
quickly turning from maximum flow to minimum
flow. If it does then remove the control knob and
make further adjustments to the gas flow, testing it
again once the adjustment has been made.
Repeat this process for each one of the gas taps.
After completing conversion,
a qualified technician or
installer has to mark "V" on
the right gas category
setting to match with the
setting in rating plate.
Remove the previous "V"
mark.