4.
Remove the plunger, flange and
gasket (flat) from the drain assembly by
unfastening the flange and pulling these
parts from the drain.
Insert the drain body up through the drain
hole from below the lavatory. If necessary,
turn the nut and push the washer and
gasket (thick) down to allow for clearance.
While holding the drain body in place,
fasten the flange to the drain body from
the top. Ensure that the gasket (flat) is
between the flange and the lavatory as
shown. Once the flange is fully seated,
turn the nut below the lavatory up until a
good seal if formed. Do not overtighten!
Reinsert the plunger if needed.
5.
Prepare the pivot arm by
placing one bushing on each
side of the pivot ball as shown.
Insert the short end of the
rod into the drain body and
through the eyelet hole in the
plunger. Fasten the pivot ball
nut to secure.
Insert the drain lift rod and
pivot arm into the drain lift rod
connecting part. Tighten both
rods with screwdriver.
Conduct tests to ensure all the
linkages are working properly
and no leaking occurs. Adjust
if needed.
INSTALLATION PROCEDURE - Drain
Plunger
Flange
Gasket (flat)
Gasket (thick)
Washer
Nut
Tailpiece
Drain Lift Rod
Pivot Arm
Pivot Ball Nut
5
Body
Bushings