TROUBLESHOOTING
Problem
Motor will not start.
Motor fails to start / runs sluggish.
Fuse / Circuit Breaker repeatedly trips.
TECHNICAL SPECIFICATIONS (as installed and tested on the unit)
Model
Model Number
Electrical
Pad/Brush Speed
Pad/Brush Size
Total Weight (w/cord)
Sound Pressure Level (ISO 11201)
Protection Grade
Protection Class
Type
Aluminum
Electrical / motors / engines - misc
Ferrous metals
Harnesses / cables
Liquids
Plastic - non-recyclable
Plastic - recyclable
Polyethylene
Rubber
A-10
INSTRUCTIONS FOR USE
Cause
No power.
Switch Lever Safety Lock Button (2) not
depressed
Defective switch / Faulty connection
Low voltage from excessive length or
undersized extension cord.
Defective start capacitor.
Defective start switch.
Defective start/run capacitor
Defective motor low voltage
Low voltage.
Bad connection.
Defective motor.
1.5HP - 115V/60Hz
14" x 20" (355mm x 508mm)
160.5 lbs. (72.8 kg)
Material Composition and Recyclability
% of machine weight
1%
38%
52%
6%
0%
2%
1%
0%
1%
FM40 ST, FM40 LX - 56091153
Action
Check power supply and connection
Depress Switch Lever Safety Lock Button (2)
before activating Switch Levers (3).
Contact an authorized Clarke Dealer.
Use a 12 Ga extension cord, not to exceed
50' length.
Contact an authorized Clarke Dealer.
Contact an authorized Clarke Dealer.
Contact an authorized Clarke Dealer.
Contact an authorized Clarke Dealer.
Eliminate extension cord. Locate power
source closer to work site. Have voltage
checked by a qualifi ed electrician.
Contact an authorized Clarke Dealer.
Contact an authorized Clarke Dealer.
FM40 ST
56105618
3540 rpm
14" x 20" (355mm x 508mm)
69dBA
IPX0
% recyclable
100%
70%
100%
67%
0%
0%
100%
0%
100%
FM40 LX
56105620
1.5HP - 115V/60Hz
3540 rpm
171 lbs. (77.5 kg)
69dBA
IPX0
2/2015