B. The following shows how to reduce total environmental impact (e.g. energy use) of the
cooking process.
1. Install the cooker hood in a proper place where there is effi cient ventilation.
2. Clean the cooker hood regularly so as not to block the airway.
3. Remember to switch off the cooker hood light after cooking.
4. Remember to switch off the cooker hood after cooking.
C. Information for dismantling.
This appliance cannot be dismantled by the user, other than that as shown in the original assembly of
the user manual.
At the end of its useful life, the appliance should not be disposed of with household waste. Check
with your local governmental authority, domestic waste disposal services or the retailer where the
product was bought for recycling advice.
Trouble shooting
Problem
Excessive vibration.
The light is on, but the
fan does not work.
Both the light and
motor do not work.
Suction
performance reduced.
Works normally but
cooking smells linger.
This appliance respects laws of the suppression of radio interference. As the Manufacturer has
a policy of continuous product improvement, it reserves the right to adapt and carry out any
modifi cation considered necessary without prior warning.
Kingfi sher International Products Limited, 3 Sheldon Square, London, W2 6PX, United Kingdom
Possible cause
The appliance is not installed
properly on the brackets.
The fan blade is damaged.
The fan motor is not fi xed tightly.
The fan blade is jammed.
The motor is damaged.
Light bulb blown.
Power connection loose.
Speed may be too low.
Aluminium fi lters
are dirty.
Top vent might be
obstructed.
Optional vent kit might be twisted.
The installation may not comply with
the manufacturers instructions.
Carbon fi lter is not fi tted in
recirculation mode or is full
of grease.
Solution
Take down the appliance and check
it is properly fi xed.
Switch off the appliance. Repair to
be carried out by qualifi ed service
personnel only.
Replace with a bulb of the
correct rating.
Check power supply.
Select a higher speed.
Clean the aluminium fi lters. (See
Care and maintenance section).
Clear any obstruction.
Ensure that the vent kit
is fi tted according to the
manufacturer's instructions.
The vent hose should be correct
diameter throughout with no
reductions or restriction.(See
installation section).
Fit carbon fi lter or replace the
carbon fi lter (See Care and
maintenance section).