Tekmar tekmarNet 532 Guía De Instalación Rápida página 4

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Setting
The following settings are available when the thermostat is unlocked.
SET LIMIT ROOM MAX
Set the max room temperature limit while in the occupied time period. Available
when a room sensor is connected.
SET LIMIT ROOM MAX
Set the max room temperature limit while in the unoccupied time period.
Available when a room sensor is connected and a schedule or scenes are se-
lected.
SET LIMIT ROOM MIN
Set the min room temperature limit for both occupied and unoccupied time periods.
Available when a room sensor is connected and schedule or scenes are selected.
SET FLOOR MAX
Set the max floor temperature in order to protect the floor covering. Available when an
auxiliary floor sensor is connected. Suggested settings: Tile = 90°F (32°C), Wood Floor
= 85°F (29°C)
SENSOR 1
Select the type of sensor connected to auxiliary input 1. Available when a sensor
is automatically detected.
SENSOR 2
Select the type of sensor connected to auxiliary input 2. Available when a sensor
is automatically detected.
ROOM SENSOR
Select when the built-in room temperature sensor is on or off. The built-in room
sensor can only be disabled when an auxiliary room or floor sensor is connected.
AIR GROUP
Select if this thermostat should be included in an air group to interlock heating
and cooling for the group. Requires tekmarNet.
W PUMP
During a heat call, select whether the tN4 system control's pump should turn on
or be off to allow a zone group pump per manifold. Requires tekmarNet.
W DELAY
During a heat call, select whether the tN4 system control's pump should be
delayed by 3 minutes to allow manifold thermal actuator zone valves to open.
Requires tekmarNet.
For a full list of settings and operational details, please refer to the Thermostat Installation
and Operation Manual 532_D that is available from www.tekmarControls.com
All specifications are subject
to change without notice
Product design, software and literature are Copyright ©2015 by tekmar Control Systems Ltd.,
A Watts Water Technologies Company. Head Offi ce: 5100 Silver Star Road, Vernon, B.C.
Canada V1B 3K4, 250-545-7749, Fax. 250-545-0650 Web Site: www.tekmarControls.com
4 of 12
532_Q - 02/15.

Publicidad

Tabla de contenido
loading

Tabla de contenido