Descargar Imprimir esta página

Stobag SKIROSOL SRCK 620 Instrucciones Y Advertencias Para La Instalación Y El Uso página 27

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
2
• "Wind" sensor (fi g. 3)
When the wind speed, measured by the sensor (a - fi g. 2), exceeds the threshold,
SRCK 620 immediately transmits the Up command to the motor. At the same time it
also sends a command that blocks execution of any other command sent to the motor,
to protect the awning from the wind.
When the wind speed falls below the threshold value, after 4 minutes SRCK 620
unblocks the awning protection to enable other automation commands. After the sys-
tem is unblocked, if the sun threshold is exceeded, after 15 minutes SRCK 620 sends
the command for awning descent.
Note - During normal operation of the product, the led remains permanently off, even
when SRCK 620 sends commands.
3
www.stobag.com
3 – PRELIMINARY INSTALLATION CHECKS AND PRODUCT APPLICA-
TION LIMITS
• Read the technical specifi cations provided in the chapter "Product technical specifi ca-
tions" to check the application limits of SRCK 620.
• Ensure that the receiver on which SRCK 620 is to be memorised uses "TTS" encoding
(refer to the automation receiver instruction manual).
• SRCK 620 may not be compatible with older motors produced before June 2004 or
TT0 control unit models.
• (fi g. 4) Ensure that the selected installation site for SRCK 620 is within the range with
respect to the motor to be controlled. Although the range in favourable conditions
(open fi eld) can reach 100m, as SRCK 620 represents a protection for the awning, a
maximum range of 10-20 m is recommended. It is also recommended to check that
there are no other radio devices in the zone operating at the same frequency, such
as alarms, radio headphones etc.: these may reduce the range further or even block
communication between SRCK 620 and the motor.
• Ensure that the selected installation site for SRCK 620 meets the following require-
ments:
– (fi g. 5) must enable direct sun exposure of the sun sensor surface, at least at the
time of day in which the sun protection of the automation must be effi cient; never
install the product in shaded areas caused by awnings, trees, balconies etc.;
– (fi g. 6) the area must ensure exposure of the wind sensor blades to the same venti-
lation as that applied on the sun awning to be automated.
• (fi g. 7) Select the type of confi guration for the SRCK 620 structure according to the
angle of the surface selected for installation. Caution! – the wind sensor blades
must be positioned horizontally facing downwards with respect to the body.
• Ensure that the selected surfaces for installation are solid and guarantee a stable fi x-
ture.
• Ensure that SRCK 620 is placed in a position protected against accidental impact with
other objects.
4 – PRODUCT INSTALLATION
For installation, fi x the various parts of the product in numerical order as shown in fi g.
8. Then rotate the body of SRCK 620 until the wind sensor blades are positioned on a
horizontal plane as shown in fi g. 7.
In general, up to 3 SRCK 620 units can be memorised on the same automation; this
enables control of different points of the environment.
27