Descargar Imprimir esta página

THERMOBILE IMAC 1200 Manual Del Usuario página 21

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
Fault
The burner is
32
producing soot.
The burner will
33
start, a flame has
been formed, but
the burner stops.
The convector
34
heater cannot be
switched off.
The convector
35
heater stops.
The convector
36
heater stops
burning. The reset
37
button lights up.
38
The convector
39
heater is producing
white smoke.
Burner
40
malfunction: the
indicator light (red)
is on.
Write down the maintenance information in table
A in the Appendix at the back of this manual.
7
SPARE PARTS
We advise you to keep spare parts in stock. See
the service manual for details.
8
TECHNICAL INFORMATION
For technical specifications, refer to table C
in the Appendix at the back of this manual.
IMAC 1200/1500/2000EC
IMAC 2000 S
Cause
The air inlet has not been
correctly set.
An error has occurred in the
burner relay.
The magnet valve or valves will
not close.
An overheating problem has
occurred in the convector heater.
The fuel-supply line or the fuel
filter is leaking.
The protective grill of the air inlet
is dirty or clogged.
The heat exchanger is blocked.
There is air in the fuel system.
There is no fuel.
The photocell is dirty.
The photocell is defective.
40.021.086 - rev 01 - 2019
40.20.927 - rev. 06 - 2011
Solution
Set the air inlet.
Reset the thermostat. See fig. 7
(G).
Contact the dealer if the error is
repeated.
Close the valve of the fuel
supply. 8 (B).
Contact your dealer.
Reduce the resistance at the
outlet.
Reset the thermostat.
Contact the dealer if the error is
repeated.
Check and replace if necessary. User
Clean the grill.
Clean the heat exchanger.
Check the fuel-supply line for
leakage.
Check whether there is fuel in
the tank.
Clean the photocell.
Replace the photocell.
English
Action
Dealer
User
Dealer
User
Dealer
User
User
Dealer
User
Dealer
User
User
User
Dealer
21