IMPIANTO ELETTRICO - ELECTRICAL SYSTEM - SYSTÈME ÉLECTRIQUE - ELEKTRISCHE ANLAGE -
INSTALACIÓN ELÉCTRICA - ЭЛЕКТРИЧЕСКАЯ СИСТЕМА - ΗΛΕΚΤΡΙΚΗ ΜΟΝΑΔΑ -
Connection between A-C
Length max = 8 m
Poles = 2
Section = 20-22 AWG
Connection between A-D
Length max = 7 m
Cable diameter: 4÷6 mm
Poles = 6
Section = 24 AWG
Connection between A-E
Length max = 7 m
Cable diameter: 4÷6 mm
Poles = 3 (GND common)
Section = 24 AWG
Connection between A-F
Length max = 10 m
Cable diameter: 4÷6 mm
Poles = 2
Section = 20 AWG
Connection between A-Serial Port (RS485)
Length max = 10 m
Cable diameter: 4÷6 mm
Poles = 2
Section = 20 AWG
WARNING:
- the connection to a cut out switch with intervention current not greater than 30mA is mandatory.
- on the supply cable "L+N" (not included), to guarantee compliance with the requirements of
Electromagnetic Compatibility, it is necessary to position the following ferrite: Trademark: Fair-
Rite Products Corp - Model: 431164281 or a component with similar characteristics.
ELECTRICAL CONNECTIONS DATA