TROUBLESHOOTING GUIDE

PROBLEM
With the key in the «AVV.»
[ON] position the instrument
panel remains off
The instrument panel comes on,
but the starter motor does not
turn with the key in «ON»
Difficult starting or
engine irregular running
The starter motor turns but the
engine will not start
Loss in engine performance
while cutting
Engine stops when
blades are engaged
Uneven cut
Vibrations while working
Engine oil light comes on
CAUTION: If the problems continue after having carried out the operations described in this
manual, contact an Authorized Service Centre. Never attempt to make difficult reparations without
the necessary means and technical knowledge.
IMPACT WITH A STONE OR SOME OTHER FOREIGN OBJECT
1) Stop the machine.
2) Turn off the engine and apply the parking brake.
3) Tilt the cutting device.
4) Check the blade fixing screws and the deck condition.

MECHANICAL PARKING BRAKE

The parking brake device wire (fig. 5, ref. B) has to be adjusted. The brake is activated by opening the
steering levers outwards (fig. 1, no. 1). To release the brake just put the steering levers back into the
working position.
Always apply the parking brake when you leave the machine.
The engine keeps running even if the driver leaves the seat, if the parking brake is engaged. If the
parking brake should be hard to apply, you can intervene on the activating wire adjusting the relevant
adjusting screws (fig. 5, ref. B).
ELECTRICAL SYSTEM
The electrical system is protected by fuses which, if blown out, cause the whole electrical system to cut out.
These are located under the driver's seat by tilting the seat for the machine inspection. There are two main
fuses (fig. 17, ref. B and C): the general fuse with 25 A/h and the one that feeds the services with 15 A/h.
Once the fault has been located and repaired, replace the blown fuse with one of the same rating.
Never replace a fuse with another of a different rating.
FX27 / Translation of the original instructions
CAUSE
The battery is not providing any
current
The battery is not providing
enough current
No consent is given to start
Carburettor problems
Sediment or dirt in the fuel
No petrol flow
Forward speed too high for the
grass height
No consent is given for blade
engagement
Cutting deck not parallel with
the ground
Blades not cutting correctly
Forward speed too high for the
grass height and the lawn
conditions
Blades not balanced
Loose screws
Insufficient pressure
- 11 -
REMEDY
- Check the connecting cables
- Recharge the battery
- Replace the fuse
- Recharge the battery
- Feed levers in the «STOP» position
- Disengage the blades
- Clean or replace the air filter
- Check that there is no air aspiration in the fuel pipes
- Bleed the supply system
- Check the petrol filter (and replace if necessary)
- Check fuel level in the tank
- Make sure that the taps on the tanks are open
- Check the petrol filter (and replace if necessary)
- Check that no silt has clogged the breather hole
in the fuel cap
- Check the solenoid on the carburettor
- Reduce speed
- Lift the cutting deck up into a higher position
- Check that there are no obstacles on the cutting
device transmission
- Check tyre pressures
- Restore deck parallelism
- Check blades are fitted properly
- Sharpen or replace blades
- Adjust PTO belt tension
- Reduce forward speed
- Balance blades or replace them if damaged
- Check and tighten the screws fastening the
blades, the engine and the chassis
- Check engine oil level and top up if necessary
- Change engine oil filter