2.3 IDENTIFICATION
Model Identification
Product
Rated
and
Size
output
series
current
Ex.: CFW700
A
03P6
Refer to table 2.2.
NB = without dynamic braking (valid only for size
E inverters).
DB = with dynamic braking.
(2)
20 = IP20
CFW700
21 = IP21 (not available for size E inverters).
N1 = Nema1 enclosure (UL Type 1) (protection degree according to
IEC: IP21 for sizes A, B and C and IP20 for sizes D and E).
Blank = it is not in accordance with the standard conducted emission levels.
C3 = according to category 3 (C3) of IEC 61800-3, with built-in C3 RFI filter.
Notes:
(1) The options available for each model are shown in
(2) This option is not available for size D inverters (the standard product is Nema1).
(3) This option is not available for size A inverters with the N1 option (Nema1 enclosure) or IP21.
(4) It is possible to meet the requirements of category C2 with this filter on mechanics A models. For further details, see
Table 2.2: Options available for each model according to the size, power supply, rated current and
Rated output
Size
current for ND
overload
06P0 = 6.0 A
A
07P0 = 7.0 A
06P0 = 6.0 A
A
07P0 = 7.0 A
10P0 = 10 A
07P0 = 7.0 A
10P0 = 10 A
A
13P0 = 13 A
16P0 = 16 A
24P0 = 24 A
B
28P0 = 28 A
33P5 = 33.5 A
45P0 = 45 A
C
54P0 = 54 A
70P0 = 70 A
86P0 = 86 A
D
0105 = 105 A
0142 = 142 A
E
0180 = 180 A
0211 = 211 A
03P6 = 3.6 A
05P0 = 5.0 A
A
07P0 = 7.0 A
10P0 = 10 A
13P5 = 13.5 A
17P0 = 17 A
B
24P0 = 24 A
31P0 = 31 A
38P0 = 38 A
C
45P0 = 45 A
58P5 = 58.5 A
70P5 = 70.5 A
D
88P0 = 88 A
0105 = 105 A
0142 = 142 A
E
0180 = 180 A
0211 = 211 A
Table 2.1: Identification of the CFW700 inverters
Number
(1)
Braking
Enclosure
Rated
of power
voltage
phases
T
4
DB
table
2.2.
voltage of the inverter
Number of
Rated voltage
power phases
B = single-phase or
2 = 200...240 V
three-phase
S = Single-phase
2 = 200...240 V
2 = 200...240 V
T = three-phase
2 = 220...230 V
T = three-phase
4 = 380-480 V
General Instructions
Conducted
Safety
External
emission
stop
(1)
control
(1)
(3)
voltage
level
20
C3
Y1
Blank = not available.
W1 = 24 Vdc power supply,
independent of the control voltage.
Blank = not available.
Y1 = with safety stop function according to
EN 954-1/ISO 13849-1, category 3.
(4)
Available options for the remaining identification
codes of the inverters
(standard product is shown in bold)
Enclosure
Braking
(protection
degree)
DB
20, 21 or N1
DB
20, 21 or N1
20, 21 or N1
DB
21 or N1
NB or DB
20 or N1
20, 21 or N1
DB
21 or N1
NB or DB
20 or N1
Special
Special
hardware
software
version
version
W1
---
--
Blank =
standard.
Sx =
special
software.
Blank = standard.
Hxx or Kxx = special
hardware.
table
B.5.
Conducted emission
level
Blank
C3
Blank or C3
Blank or C3
C3
Blank or C3
C3
CFW700 | 5