EXPLOSION PROTECTION IDENTIFICATION
X marking:
The spray gun corresponds with Ex II 2G c IIC T6 X and is, in accordance
with Directive 2014/34 EU, suitable for use in explosion-hazardous
areas—as of type Zone 1. Under certain circumstances, the unit itself
may cause the Zone 1 condition to be in effect.
Any static-electricity discharge from the spray gun is to be diverted to
the grounded high-pressure pump via the conductive high-pressure
hose as stipulated.
The maximum surface temperature corresponds to the permissible
material temperature. This and the permissible ambient temperature
can be found in the Technical Data.
To avoid the generation of machine sparks, prevent impact stresses and any
work on the unit with tools in the explosion-hazardous area.
Residual risks
Residual risks are risks, which cannot be excluded, even when equipment is
used for the intended purpose.
In such cases the applicable areas of the actual residual risks will be pointed
out using warning and/or prohibition signs.
Risk
Injection
injury
Explosion or
fire
Hazardous
vapors
4
Source /
Cause
High pressure
stream of
fluid
Static
electricity or
sparks
Hazardous
vapors
from spray
material
Impact
Preventative
measures
Severe
NEVER aim the
injury or
gun at any part
amputation
of the body
Severe injury Use well
ventilated area
Ground the
spray gun
Severe injury Use well
ventilated area
Use respiratory
Can occur
during:
Setup,
Operation
Operation
Operation
M-4/M-8
GB