Descargar Imprimir esta página

Fafnir TORRIX M12 Manual De Instrucciones página 28

Publicidad

Schedule to EU-Type Examination Certificate No. TÜV 99 ATEX 1496 X
TORRIX Exd XT...; TORRIX Exd ...-A; TORRIX Exd ... Flex and TORRIX Exd ... PL:
Signal and power supply
(Terminals +, -, A, B)
Heating circuit
(Terminals -, +)
Thermal data:
VISY-Stick ...; VISY-Stick (Flex) Temp; TORRIX Ex SC...; VISY-Stick Advanced ...;
VISY-Stick ... Flex ...; TORRIX Ex SC...-A; TORRIX Ex SC... Flex and TORRIX Ex SC... PL:
For EPL Ga or EPL Ga/Gb or EPL Gb, the permissible temperature range depending on the
variant and the temperature class can be taken from the following table:
Temperature class
T6
T5
T4
T3
T2
T1
For EPL Db applications, the permissible ambient temperature range depending on the
permissible surface temperature can be taken from the following table:
Dust layer ≤ 5 mm
T
5
X°C = T
The equipment is suitable for dusts with an ignition temperature of more than 190 °C under a
dust layer of 5 mm (glow temperature).
P17-F-011
Ambient temperature range
-40 °C ... +50 °C
-40 °C ... +65 °C
-40 °C ... +85 °C
-40 °C ... +85 °C
-40 °C ... +85 °C
-40 °C ... +85 °C
Maximum surface temperature
X°C
+ 30 °C
a
This certificate may only be reproduced without any change, schedule included.
Excerpts or changes shall be allowed by the TÜV NORD CERT GmbH
Rev. 02/11.21
For connection to non-intrinsically safe circuits with
the following values:
U = 12 V
... 50 V
d.c.
d.c.;
U
= 253 V
m
For connection to non-intrinsically safe circuits with
the following values:
U = 24 V
± 10 %
d.c.
I = 160 mA
With total immersion
T X°C
X°C = 135 °C
Issue 03
I = 4 mA ... 20 mA
Medium temperature range
-40 °C ... +75 °C
-40 °C ... +90 °C
-40 °C ... +125 °C
-40 °C ... +190 °C
-40 °C ... +285 °C
-40 °C ... +435 °C
Ambient temperature range
T
a
-40 °C ... +85 °C
Page 5/8