15. TECHNICAL CHARACTERISTICS
COMPACT. TABLE I
Slots
Slots occupied
Slots free
Ethernet communication
CAN Bus
VoIP
Input contacts
Output contacts
Audio inputs
Internal audio channels
SD memory for pre-recorded messages
Power supply
Consumption
Weight
Finishes
Measurements
Rack units
CARD UMX-C16. TABLE II
Position in COMPACT
Input contacts
Output contacts
Power supply
Indicators
Consumption
CARD UMX-EA3. TABLE III
Position in COMPACT
Audio inputs
Controls
Input sensitivity
Signal/noise ratio
Frequency response
Input impedance
Power supply
Indicators
Consumption
COMPACT version 5.0.002
COMPACT
10
2 (slot 1: UMX-C16, slot 2: UMX-EA3)
8 (slots 3 to 10)
2 Ethernet connections (RJ45) A and B for redundant installations. IP Layer 3 & Layer 4
Network.
Communication with the COMPACT-E slave matrix and peripherals.
SIP RFC3261 protocol.
G711 coding (PCMA and PCMU), G722 and L16.
3 Input contacts on the control module. Configurable NC/NO. May be monitored.
16 input contacts on the UMX-C16 card (see table II). May be monitored.
The detection time of the activation pulse of the input contacts is configurable through
the Call Point software (0-50-100-200-300-400-500-1000-1500-2000 milliseconds).
3 Output contacts on the control module. Configurable NC/NO.
1 FAIL relay. Max. DC charge current: 150 mA. Max. DC or AC peak charge voltage: 350 V.
4 output contacts on the UMX-C16 card (see table II). Dry contacts or referenced to
ground.
1 Front USB 2.0 as music input. DC output: 5V / 0.2A. Supports wav, mp3 and OGG
files.
2 Audio inputs on card UMX-EA3 (characteristics in Table III).
16
16 GB
24 VDC. Dual power supply (primary and secondary).
730 mA (without cards).
9 kg
RAL9005 iron painted black.
482.6 (width) x 133 (height) x 280 (depth)
3
Slot 1. Additional UMX-C16 cards may be inserted in slots 3 to 10.
16
4
Through the COMPACT.
Power indicator light.
100 mA
Slot 2. Additional UMX-EA3 cards may be inserted in slots 3 to 10.
2 (input A: RJ45/connector XLR; input B: RJ45)
Independent volume potentiometer for each input.
0 dBm
-20 dBm
> 73 dB
> 73 dB
50 Hz ~17.5 kHz
50 Hz ~17.5 kHz
1.2 KΩ / 220 KΩ
Through the COMPACT
Power indicator light
100 mA
-60 dBm
> 52 dB
100 Hz ~15 kHz
R +D Department
Modular audio matrix
with IP connection
-60 dBm + speech filter
> 52 dB
300 Hz ~10 kHz