14. Errors
The control panel can detect the following errors:
control panel Low Battery
AC Power Fail
Sensor Out-of-order
Sensor Low Battery
Device and control panel Tamper
Interference Detection
SIM card missing
GSM out of signal
If the control panel detects an error, it will display an error.
Possible errors
Control panel
A tamper switch prevents the device from any removal attempts away
from its cross mounting bracket
Power supply
A tamper switch protects the power supply lid from being opened or
removed.
PIR Sensor
A tamper switch protects the enclosure from being opened.
A back-tamper protects the unit from being removed from its mounting
location.
Door contact
A tamper switch protects the enclosure from either being opened or being
removed from the mounting surface.
Sensor Low battery
The device detects low battery for the PIR sensor, door contact, remote
keypad, water sensor, remote controller.
Sensor out-of-order
The PIR sensor, door contact, water sensor will send signals to the panel
at intervals between 30~50 min. The system will send an out-of order
report if a device no longer sends a supervision signal.
If the control panel does not receive the supervision signal from the device
(see section Supervision in Chapter 8 Special Settings), the control panel
will sound an alarm and yellow LED will light while an error message can
be viewed on the LCD (in the Fault Display menu).
Interference
The device can detect interference on 868 MHz frequency band.
After a continuous interference signal is present for more than 30 seconds,
an interference event can be logged, displayed on the LCD (in the Fault
Display menu).
SIM Card missing
If the SIM card is missing, a warning message will be shown.
GSM out of signal
If out of signal, change the position of the control panel to get a better
signal.
Fault message display
When any error persists, the control panel will respond as below when it is disarmed:
The yellow LED will light to indicate the error
The LCD will display the type of error and the source of the error in the Fault Display section of the user
menu.
A warning beep will sound every 30 seconds.
If an error is detected while the system is in full arm mode, the error will not be shown until the system is
disarmed.
Clearing error message display
The yellow LED will turn off automatically once all errors are restored, or any devices in error are removed. It
cannot be cleared manually.
The error message display remains even if the errors have been restored.
The error message can only be cleared manually after the error has been corrected.
Viewing/clearing the error message
To check the error, when the system is disarmed.
1. Enter your pin code and press OK.
V. 04 – 11/02/2016