CLEANING THE FUEL FIL-
TER AND TANK.
Remove and replace the in-
line fuel filter (fig. 16).
Change it from time to time.
Empty the fuel tank.
Open the drain cap (fig. 17) (if
available) and let any impuri-
ties drain out into a container.
Flush out the tank with clean
fuel and close the drain cap.
CLEANING THE WATER
FILTER
Clean the water intake filter
regularly and free it from any
impurities (fig. 18).
CHANGING THE NOZZLE
The high pressure nozzle fitted on the lance must be chan-
ged from time to time, as this component is subject to
normal wear during use. Wear may generally be detected
by a drop in the working pressure of the cleaner. To repla-
ce it, consult your supplier and/or dealer for instructions.
DESCALING
Descaling must be carried out from time to time because the
scale present in the water partially deposits inside the hydraulic
circuit and the coil which with time becomes clogged.
Apply to our technical service centre to have the machine
descaled from time to time; this will save you money and
increase the efficiency of the cleaner.
English
TABLE OF ROUTINE MAINTENANCE TO BE PER-
FORMED BY THE USER
Description of operations:
Check power cable - pipes - high pressure
connectors
Ist oil change in H.P. pump
Subsequent changes in H.P. pump
FIG.16
Change and clean fuel filters
Clean fuel tank
Clean water filter
TABLE OF
BE PERFORMED BY THE TECHNICAL SERVICE
CENTRE
Description of operations:
Boiler:
Clean Coil
FIG.17
Descale coil
Clean fuel pump
Change fuel nozzle
Regulade electrodes
Change electrodes
Change seals on H.P. pump
Change lanze nozzle
Calibrate and check the safety devices
FIG.18
- 28 -
EXTRAORDINARY MAINTENANCE
Each use
After 50 hours
Every 500 hours
Every 100 hours
Every 100 hours
Every 50 hours
TO
Every 200 hours
Every 300 hours
Every 200 hours
Every 200 hours
Every 200 hours
Every 500 hours
Every 500 hours
Every 200 hours
Once a year