FAULTS
When the temperature regulator is
brought to the required position, the
boiler does not come on.
Water not enough.
Excessive smoke from exhaust.
Inadequate detergent suction.
Water leakage from head.
Water in the oil.
N.B. To reset the indicators, rotate the main switch "A" (fig. 8) to the "O" position and then to the "I" position.
For maintenance and/or repairs, use only original spare parts which offer the greatest characteristics of quality and
reliability. Failure to use original spare parts frees the manufacturer from all responsibility.
English
CAUSES
No diesel.
Motor rotation direction incorrect on
three-phase models.
Temperature regulator position.
Filters clogged.
Boiler element coated with scale.
Incorrect combustion.
Fuel contaminated with impurities or
water.
Tap closed.
No detergent.
Element or tube clogged.
Gaskets worn.
Excessive humidity in atmosphere.
Refer to the "Control Panel".
IMPORTANT:
- 30 -
REMEDIES
Check the level of diesel in the tank and
make sure the fuel supply circuit is free
of water.
Contact Service Centre.
Check.
Clean or replace.
Contact Service Centre.
Clean or replace diesel filters.
Contact Service Centre.
Empty the tank and clean thoroughly.
Clean diesel filters.
Open.
Fill the detergent tank.
Contact Service Centre.
Contact Service Centre.
Replace oil.