3.6 Digital outputs (connector CN1)
Use the following pins as a reference for the ground connections: pins CN3-12 (see paragraph 3.2).
CN1-7
Wire 13
(Imax = 100mA)
CN1-8
Wire 15
(Imax = 100mA)
CN1-15
Wire 14
(Imax = 100mA)
CN1-16
Wire 16
(Imax = 100mA)
PROGRAMMABLE PARAMETERS:
GAS CYCLE :
SAFETY LIMIT WARNING :
SAFETY LIMIT ALARM :
WELDING TOOL READY: this signal confirms that the welding tool is ready for use (none of the
system's alarms are active).
0V = system in alarm status
24V = welding tool ready for use
ARC ON: signal confirming that the electrical arc has been powered up.
0V = arc OFF
24V = arc ON
PROGRAMMABLE DIGITAL OUTPUT 1 (DO1): the parameter for this digital output can be selected
and programmed by control panel.
Default : not programmed
0V = digital output inactive
24V = digital output active
PROGRAMMABLE DIGITAL OUTPUT 2 (DO2): the parameter for this digital output can be selected
and programmed by control panel.
Default : not programmed
0V = digital output inactive
24V = digital output active
confirmation signal of gas cycle active.
0V = gas cycle inactive
24V= gas cycle active
confirmation signal of safety limit no warning active.
0V= safety limit warning active
24V = safety limit warning inactive
confirmation signal of no alarms.
0V = safety limit alarm active
24V = safety limit alarm inactive
CN1-7 (13)
CN1-8 (15)
DO1 CN1-15 (14)
DO2 CN1-16 (16)