Descargar Imprimir esta página

EuroLite TF-5 DMX-Flower-Effect Manual Del Usuario página 27

Publicidad

Idiomas disponibles

Idiomas disponibles

DMX-protocol
Control channel 1 - Gobo-wheel, gobo-shake
DMX-Value Feature
0-5
Blackout
6-39
Strobe-effect
40-45
Open
46-51
Gobo 1
52-57
Gobo 2
58-63
Gobo 3
64-69
Gobo 4
70-75
Gobo 5
76-81
Gobo 6
82-87
Gobo 7
88-93
Gobo 8
94-99
Gobo 9
100-105
Gobo 10
106-111
Gobo 11
112-117
Gobo 12
118-123
Gobo 13
124-129
Open
130-135
Gobo 1 shake with increasing speed
136-141
Gobo 2 shake with increasing speed
142-147
Gobo 3 shake with increasing speed
148-153
Gobo 4 shake with increasing speed
154-159
Gobo 5 shake with increasing speed
160-165
Gobo 6 shake with increasing speed
166-172
Gobo 7 shake with increasing speed
173-177
Gobo 8 shake with increasing speed
178-183
Gobo 9 shake with increasing speed
184-189
Gobo 10 shake with increasing speed
190-195
Gobo 11 shake with increasing speed
196-201
Gobo 12 shake with increasing speed
202-207
Gobo 13 shake with increasing speed
208-225
Stop
226-255
Cont. gobo-wheel rotation with increasing speed
Control channel 2 – Flower Rotation
DMX-Value
Feature
0-26
Stop
27-130
Red with increasing speed
131-149
Stop
150-255
Red with decreasing speed
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
27/55
00025987.DOC, Version 1.3

Publicidad