to achieve higher performance).
! Do not wash the device under running water or
immerse it in water!
Do not use indoors.
Do not exceed a height of 2135m above sea level.
Make sure that the ambient temperature is between
+40 and -25 ° C and that the relative humidity does
not exceed 90%.
! The generator must be grounded to prevent electric
shock. Use an insulated wire to connect the generator
ground connection and the external ground.
It is necessary that the connection of the generator
to the el. network and grounding by an authorized
person.
Improper connection between the generator and the
appliance can cause damage to the generator, or fire
or injury.
SAVE THESE SAFETY INSTRUCTIONS !!!
DESCRIPTION
1 Control gate
2 Control panel
3 Battery plates
4 Front cover
5 Left door
6 Top plate
7 Rubber cover
8 Alternator flap
9 Alternator
10 Damper cover Insulating cover
11 Exhaust muffler
12 Engine
13 Muffler assembly
14 Silencer
15 Battery
16 Inner cover
17 Protective cover
18 Rear cover
19 Bottom plate
20 Fuel tank
21 Wheel
22 Locking wheel
23 Door lock cover
24 Right door
Pictograms
Pictograms on the product packaging:
a) Power supply values
b) Maximum power
c) Continuous performance
d) Engine idling speed
e) DC voltage output
f) Fuel tank volume
g) Engine displacement
h) Weight
i) Max. altitude
j) Protection class - Type of protection
USE AND OPERATION
ASIST devices are intended for home or hobby use
only.
The manufacturer and importer do not recommend
using this device in extreme conditions and under
high loads.
Any additional requirements must be the subject of
an agreement between the manufacturer and the
customer.
Check before operation
1. Oil level
Note: Check the oil level before each start-up.
Open the right door, you will see the oil mark. Loosen
the oil dipstick, clean it with a cloth, and then insert
it into the filter neck (do not screw ). Adding engine
oil, if it is below the lower limit (including the lower
limit) when removing, methods of adding oil as below.
(7.1.), Finally, install and insert the oil dipstick.
Warning: It will cause serious engine damage if the
generator runs in a lack of lubricating oil.
2. Fuel level
Caution: Refuel in a well-ventilated area, make sure
there is no smoke or fire and sparks when refueling.
Open the left door, check the fuel gauge. If the fuel
level is low, unscrew the tank cap and add fuel throu-
gh the fuel filter. After adding fuel, screw the tank cap
back on.
If the generator will not operate for a period of time,
drain the remaining fuel through the drain hole at the
bottom of the fuel tank (located at the bottom of the
generator under the panel).
Check the battery for damage, if damaged, replace
the battery.
Three-phase control panel
52