Slide the plastic rounded cover on the top of the unit,
unscrew the oil cap, fill with oil until you reach the
maximum limit of the oil dipstick (4.1. ), close the cap.
Air filter
- ! A dirty air filter prevents the passage of air, resul-
ting in reduced engine performance. Therefore, clean
the filter regularly.
Slide the top plate and back cover of the generator,
you will see the air filter. Release the clip, remove
the bottom half of the air filter and take out the filter
element in the middle; wash the filter insert and put it
back in the air cleaner after drying.
Fuel filter maintenance
Set the fuel cock to the „OFF" position.
Thoroughly clean the fuel filter container, blow it out
with compressed air in the direction of the arrow.
Firmly install the new rubber pad and filter bowl.
8 hours or
daily
Oil control
X
Oil change
Air cleaner element
X
control
Air cleaner element
replacement
Valve clearance
check
Battery fluid check
X
Oil filter check
Oil filter replacement
Fuel filter
replacement
Every two
Fuel line
years
20
100 hours
hours or
or quarterly
monthly
X
X
X
X
X
X
X
54
After the first 10 hours of operation, a complete
inspection of the device and cleaning of all filters is
required.
(oil, fuel, spark plug, fuel lines, filters, strength of
connections),
Recommended oil
Oil for 4-stroke diesel engines, API CE, CF
same as CG oil (SAE10W-30).
Possible defects
The following problems may occur during operation:
The generator does not start:
If the engine fails to start, try checking the following:
1. Check the fuel level. (Turn fuel tap to "ON" position)
2. Turn the engine switch to the "ON" position
3. Check whether the fuel supply is blocked.
4. Defective ignition system - consult with the seller or
authorized service.
! If the engine still cannot be started, do not attempt
to repair the generator, but take it to an authorized
service center.
The generator does not supply voltage
1. Check that the AC/DC protection is in the "ON"
position.
2. Check if the device has been properly connected to
the generator.
3. Unplug the device from the outlet.
Contact an authorized service
CAUTION: If you want to store the generator for an
extended period of time, you must perform the follow-
ing procedure:
Drain the fuel tank and carburetor float chamber. Pour
a little engine oil into the tank.
Shake the tank. Drain excess oil.
Fill the lubricating oil up to the maximum mark on
the oil dipstick. Using a hand starter, turn the engine
several times (with the ignition off). Pull out the hand
starter until you feel resistance.
Stop pulling.
Clean the outside of the generator and apply an