Poste externe audio

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

'Free': when pressing the door lock release button of an apartment station, the door unit electric lock can
be activated only if the door unit is confi gured as main or the user belongs to the column of the same
secondary door unit. This column is defi ned by the ID setting of the secondary door unit. This function is
typically used for secondary stations.
The above applies to the vehicle and pedestrian gate electrical lock.
Interruption: where is in progress an auto-on or an intercom conversation or the video door phone answering
machine browsing, the respective column or the whole system is in busy mode, which, according to the
confi guration of this switch, can be interrupted or not by a call from the door unit.
The parameter "interruption" must be programmed in the same way for all system call stations.
Camera LED operation: the camera LEDs can be confi gured to light up (if the camera is connected) during
calling and auto-on phases.
Station type
Secondary station
address
Door opener
Interruption
Camera LED on
24
All manuals and user guides at all-guidesbox.com
ON
DIP
Main
1
2
3
4
5
ON
DIP
Secondary
0
1
2
3
4
5
ON
DIP
Door opener
free
1
2
3
4
5
ON
DIP
On
1
2
3
4
5
ON
DIP
Off
1
2
3
4
5
ON
DIP
Secondary
1
2
3
4
5
ON
DIP
Secondary
1
1
2
3
4
5
ON
DIP
Door opener
privacy
1
2
3
4
5
ON
DIP
Off
1
2
3
4
5
ON
DIP
On
1
2
3
4
5
AUX
DS1083-056B

Publicidad

loading