ELDA - CORONA
6.3
OPTIONAL PROBE AND EXTERNAL THERMOSTAT
The standard unit controls the room temperature via a room probe which has the function of regulating the output
according to the set temperature.
Upon request, the user can have an external thermostat or an optional probe installed by an authorized service
center, to be connected directly to the motherboard, whose sensor can be positioned in the most suitable place.
For any choice it is necessary to contact an authorized technician who will provide for installation of the optional
component, the correct setting of the software parameters and the functional check.
If the thermostat-chronothermostat is installed, T-E will also be displayed on the control panel of the unit.
7.
UNIT USE
7.1
CHECK BEFORE TURNING ON
Before turning on the unit, the following points need to be checked:
▪ make sure to have read and understood the manual;
▪ follow the verbal instructions on operation of the unit provided by the installer before use;
▪ the hopper must be loaded with pellets with the door closed;
▪ the combustion chamber must be clean;
▪ the brazier must be completely free, clean of any combustion residues, complete with flame baffle and positioned
correctly in the brazier holder seat;
▪ check the hermetic closure of the fire door;
▪ check the connection of the power cable and switching to ON/1 of the power line switch.
▪ check the closure of the safety valve, the efficiency of the seal and its operation.
At first startup, remove all the components that could burn from the firebox
(instructions/label).
The unit must not be operated without its cladding.
Avoid the creation of smoke and unburnt products during lighting and/or normal
operation; an excessive accumulation of unburnt pellets in the brazier must be
eliminated manually before carrying out relighting.
Any lightings done after long idle periods require complete cleaning of the
combustion chamber and the removal of any pellets left in the hopper, in being
damp fuel no longer suitable for combustion.
In case of lighting after a long period of inactivity, restore any remains of pellets left
inside the hopper for some time and carry out complete cleaning of the combustion
chamber.
Each time the unit is turned on, check the correct position of the flame baffle and
the brazier on the brazier holder.
IT IS FORBIDDEN to use the unit without the flame baffle.
Its removal compromises the safety of the product and voids the warranty.
In case of wear or deterioration, request replacement of the part from the Service
Center (Replacement which is not covered by the product warranty in being a part
subject to wear).