8.3.3. CLEANING THE GLASS
To clean the glass, proceed as described:
Step
Action
1
Open the fire door.
The glass can be cleaned on the outside and inside using a damp cloth and specific non-abrasive
2
detergents.
3
The door must be closed after cleaning.
NB: When doing this, make sure the seals around the glass and the seal on the door are in good condition; failure
to check these seals can compromise the unit's operation. However, poor quality pellets can cause the glass to
blacken and/or deteriorate.
Do not turn on the unit with the GLASS cracked or damaged.
8.3.4. CLEANING THE AIR INTAKE PIPE
Dust can accumulate inside the inlet pipe, which over time can limit the flow of combustion air: periodically, every
4 - 6 months of operation, carry out a check and, if necessary, clean the inside using suitable equipment (air blower
or suitable brushes).
8.3.5. CLEANING THE ROOM FAN
Any deposits of dust on the fan blades lead to an unbalance of the impeller causing an increase in noise during
operation.
Therefore it is necessary to provide for adequate cleaning to be carried out only by an authorized service center.
8.3.6. CLEANING THE FUME EXTRACTOR AND COMBUSTION CHAMBER
The combustion chamber must be cleaned at least once a year, removing all combustion residues from the internal
baffles and flueways. This operation must be carried out by an authorized service center.
Any bumping or forcing can damage the fume extractor, making it noisy
during operation, therefore it is advisable to have this operation carried out
by qualified personnel.
The inspection doors have seals, so before refitting them make sure the
seals are not worn and/or damaged.
206