8. Maintenance and troubleshooting
Prior to carrying out any maintenance work, the pump must be separated from the electrical
mains. If you fail to separate the unit from mains, there is a risk of an inadvertent start of the
pump.
We decline any liability for damage caused by inappropriate repair attempts. Any damage
caused by inappropriate repair attempts will avoid all warranty claims.
Observing the conditions of use and the ranges of application of the present device will reduce the risk of possible
operational malfunction and contribute to extend the lifetime of your unit. Sand and other abrasive matters
contained in the liquid discharged will speed up the process of wearing and tearing and accelerate the drop in
performance. If the unit is operated properly, it will not require any maintenance. Where applicable, you may clean
the hydraulic part from sediments and dirt. This can be done by counter-flushing the unit with clear water using a
hose to be connected through the pressure port of the pump. To remove tenacious dirt, the foot of the pump (8)
can be removed by loosening the screws located at the bottom of the pump. To avoid any hazard, any further
disassembly as well as the replacement of parts must only be done by the manufacturer or a by an authorised
service provider.
Water left in the pump may freeze in case of frost and thus cause considerable damage. Therefore, the pump
must be removed from the liquid being discharged and fully drained when temperatures are below the freezing
point of the liquid. Please store the pump in a dry, frost-protected place.
In the case of malfunction, you should first of all check whether it was caused by an operating error or some other
reason which cannot be attributed to a defect of the device - for instance a power failure.
The list below shows some possible malfunctions of the device, possible causes and tips on their elimination. All
the measures referred to may only be carried out with the pump being separated from the electrical mains. If you
yourself feel unable to eliminate any of these malfunctions, please contact the customer service department or
your point of sales. Any repair beyond the scope specified below must only be performed by qualified staff.
Please bear in mind that all warranty claims will become void in the case of damage caused by inappropriate
repair attempts, and that we decline any liability for any ensuing damage.
MALFUNCTION
1. The pump is not
1. No current.
discharging any
liquid, the motor is
not running.
2. Thermal motor protection feature has
3. The capacitor is defective.
4. The pump wheel is blocked.
5. The floating switch is defective.
2. The motor is
1. The intake openings are clogged.
running, but the
2. The pressure line is clogged.
pump is not
3. Air penetrates into the pump body.
discharging any
liquid.
4. The min. suction level was fallen short
5. Check valve (non-return valve), if
12
POSSIBLE CAUSE
triggered. (for information on
operation with liquids > 50°C, see the
note in Technical data).
of; possibly incorrect setting of the
floating switch, motion of floating
switch restricted, floating switch
defective.
present, is blocked or defective.
1. Please use a device complying with GS
(German technical supervisory authority)
to check for the presence of voltage
(safety information to be observed!).
Please verify the correct position of the
plug.
2. Separate the pump from the electrical
mains, allow the system to cool down,
eliminate cause.
3. Please contact the customer service
department.
4. Eliminate blocking of pump wheel.
5. Please contact the customer service
department.
1. Remove possible congestion.
2. Remove possible congestion.
3. Start pump several times so that the
entire air will be driven out.
4. Make sure that the minimum suction
level is not fallen short of; if necessary,
adjust floating switch properly or make
sure that it can move freely; in the case
of a defective floating switch, please
contact customer service.
5. Eliminate blocking of the check valve
(non-return valve) or replace, if
damaged.
5