Descargar Imprimir esta página

Husqvarna DE 110 H Manual De Usuario página 23

Ocultar thumbs Ver también para DE 110 H:

Publicidad

Idiomas disponibles

Idiomas disponibles

Error
Error
code
High supply volt-
4
age.
Main Pressure
5
Sensor Error.
PCBA tempera-
6
ture too high.
7
Fan malfunction.
One wire com-
9
munication not
detected.
To move the product short distances
Make sure that the intake valve is closed. Make sure
that the dust caps are on the hoses.
1. Put the product down on the ground.
1587 - 011 - 06.03.2023
Description
Product shuts down/does not
start.
+ Warning diode light on HMI.
Prefilter light flashes red.
Product shuts down/ does not
start.
+ Warning diode light on HMI.
Product shuts down/ does not
start.
+ Warning diode light on HMI.
Product shuts down/ does not
start.
+ Warning diode light on HMI.
Transportation, storage and disposal
Probable cause(s)
Too high voltage in grid/power
supply.
Wrong battery used.
Vacuum hose is disconnected
or blocked.
Control unit is damaged.
Too high ambient temperature.
Fan is damaged or disconnec-
ted.
Control unit is damaged.
Cable disconnected or dam-
aged.
2. Lift the product manually.
Action(s)
Make sure correct
grid/power supply is
used.
Use correct battery.
Speak to an ap-
proved service agent.
Do not use the prod-
uct outside specified
temperature range.
Speak to an ap-
proved service agent.
Speak to an ap-
proved service agent.
23

Publicidad

loading

Este manual también es adecuado para:

De 110 shDe 120 h