2.4
REMOTE MEMORIZATION OF FURTHER RADIO CODES
Note: P3 button is located inside the transmitter. The added radio code will have the same functions of
the code used for the memorization. This procedure is compatible with any type of transmitter.
Memorized
Memorized
P3
continuous
sound
< 5 s
Press the button P3 of the memorized transmitter. The buzzer emits a
continuous sound. Press the button relative to a memorized code. The sound
stops for 1 second then it starts again. Press the button relative to the new
code. The memorization is indicated by an intermittent sound of the buzzer.
3.1
WIND SENSOR
The anemometer (ANEM4) detects wind speed, which the control unit compares with the threshold set through DIPs 3-4 (see table).
The control unit is only compatible with anemometers generating 4 pulses per rev.
ACTIVE ALARM when
The measured speed is higher then
the set threshold (see the table).
3.2
RAIN SENSOR
ACTIVE ALARM when
The sensitive surface of the sensor
detects any drops of water.
New
continuous
sound
1 s
< 5 s
Alarm priority
HIGH
Once ACTIVE ALARM
The control unit moves the louvres to the 50% of complete
opening and it doesn't execute any command. LA flashes.
Once ACTIVE ALARM
The control unit moves the louvres to the complete closing and
it doesn't execute any command. LR is ON.
2.5
REMOTE DELETION OF A RADIO CODE
Note: P3 button is located inside the transmitter.
Memorized
...
P3
3x
Press 3 times the button P3 of the memorized transmitter. The buzzer emits a
slow intermittent sound. Press the button relative to the code to delete within
5 seconds. The buzzer will stop sounding.
LA flashes
DEACTIVATED ALARM when
The sensor measures a speed lower than
the set threshold for at least 30 seconds.
LR ON
DEACTIVATED ALARM when
The sensor doesn't detect any drop.
15
To delete
...
intermittent
sound
< 5 s
Factory setting
ACTIVATED
DIP3 DIP4 Km/h
OFF
OFF
OFF
ON
OFF
ON
Factory setting
ACTIVATED
40
ON
50
60
ON
70