Mounting instructions
In-line axial fans
The TDM-100 has been manufactured in accordance to the rigorous standards of
production and quality as laid down by the international Quality Standards ISO 9001.
All the components have been checked and all the fi nal products have been tested at
the end of the manufacturing process.
Check that the appliance is in perfect conditions when unpacking, as any manufacturing
fault is covered by the S&P guarantee.
The installation procedure must be done in accordance to the electrical standards in
force in your country.
Installation
– The TDM-100 has been designed to be either buit-in or duct mounted. In both
cases, the hole or the duct diameter must be 100 mm.
– Once installed, check that the propeller turns freely.
– Connect the electrical wire to the terminal box, feeding it through the cable fi xing
clamp.
Electrical connection
– The TDM-100 is a class II unit (double insulation) and does not need earth connection.
– The fan can be controlled by an independent switch or by a light switch. It can also
be started by an higrostat or an air quality sensor.
– The electrical installation must incorporate a single pole switch with an air gap of
at least 3 mm.
– In bathrooms, the unit must be installed in such a way that it is out of the reach of
a person who is under the shower or the bath. The switch must either ceiling pull
cord operated or installed outside the bathroom.