Descargar Imprimir esta página

Homewerks 7140-50-G3 Manual Del Usuario página 10

Publicidad

Idiomas disponibles

Idiomas disponibles

EXISTING CONSTRUCTION INSTALLATION INSTRUCTIONS (Continued)
11. Plug the fan motor plug into the fan housing (A). Place the fan
motor back into the fan housing (A), aligning the duct with the
duct opening in the fan housing (A), and attach the fan motor
to the housing using the three screws removed in step 5.
12. Attach grille (B) by pinching the mounting springs and
inserting them into the narrow rectangular slots in the
fan housing (A).
Turn on power source. Test the unit.
CARE AND CLEANING
CAUTION: Before attempting to clean the fixture, disconnect the power to the fixture by turning the breaker off or removing the
fuse from the fuse box.
See safety information before proceeding. Routine maintenance should be done at least once a year.
• Never use solvents, thinner or harsh chemicals for cleaning the fan.
• Do not allow water to enter the motor.
• Do not immerse metal parts in water.
• Do not immerse resin parts in water more than 140°F.
WARNING: RISK OF ELECTRIC SHOCK!
Ensure the electricity to the wires you are working on is shut off.
Either remove the fuse or turn off the circuit breaker before
cleaning.
All manuals and user guides at all-guides.com
10
11
A
12
Housing
slots
Mounting
springs
4 hole
Fan motor
plug
Fan motor
A
B
Homewerks.com

Publicidad

loading

Este manual también es adecuado para:

7140-80-g37140-110-g3