LIGHT
24V DC
MOTOR
1
MOTOR
2
LOCK
(*)Depending on which side the motor 1 and motor 2 are placed the red and blue wires of each
motor must be interchanged.
In the circuit there are light indicators (4 LED) behind the motor connections. The door
should open when the green indicator light comes on and close when the red light
comes on. Swap the brown and blue wires if the door closes when it should open and
open when it should close.
The output for the blinker is active during the entire maneuver (included with the door
open) and deactivated 1 minute after finishing the closing.
4.2 Control connector
½ (COM)
P.SW CL OP
P.SW
24V (+ -)
IR (COM)
COM
+PWR (COM)
*N.O= Nomally Open.
** The door in the automatic mode, closes the leaf by itself, but the door in not automatic mode,
you have to press once the transmitter with the P.SW CL contact or the P.SW contact.
Contact inputs ½ , IR and +PWR use COM as second connection.
If photocell is not installed a wire bridge must shortcircuit IR and COM.
8
+
-
+
-
-
+
Single leaf** open/close N.O* contact
Open / close N.O* contact
Close N.O* contact
24 V. accesories power output
Photocell N.C contact
Signals common and negative power output 24VDC-
24 VDC+ accesories power output
Blinker
Blinker
Motor 1 blue(*)
Motor 1 brown(*)
Motor 2 red(*)
Motor 2 blue(*)
Electric lock (24V.)
Not included