Cleaning the filter and diesel tank.
Remove the filter on the diesel circuit and replace it.
Replace regularly (fig. 7).
Empty the diesel tank.
Using the drainage bung (fig. 8), drain any impurities present
into a container.
Rinse the tank with clean diesel and close the drainage hole.
DESCALING
The appliance must be descaled regularly to avoid the risk of
calcium in the water building up in and blocking the water circuit
and coil.
This should be done by an authorised technical service
centre and will increase the efficiency of the heat genera-
tor.
If the hot water generator is not used for long periods, unplug
from the mains socket and protect parts which might be dam-
aged by dust. Empty the water circuit and rinse with clean
water.
When used again, check there are no cracks or cuts in the
feed pipe.
SCRAPPING
If you decide to stop using the hot water generator, you should
render it inoperative by removing the electric power cable. Parts
which might constitute a danger, especially to children playing
with the appliance, should be made harmless.
This product is classified as WEEE type special waste and is
covered by the requisites of the new environmental protection
regulations. It must be disposed of separately from ordinary
waste in compliance with current legislation and standards.
Do not use the components removed as spare parts.
STANDARD KIT
H.P. feed pipe l = 3.0 m
TECHNICAL CHARACTERISTICS
Boiler volume
l
Min. flow rate
l/min.
Max. flow rate
l/min.
Working pressure bar
Water temp.
°C
Heat input
W
Heat output
kW
Diesel tank
l
Weight Kg
Noise level
Lp dB (A)
STORAGE
30
40 - 40/35
3,9
5,0
6
6
21
21
175
200-350
140°
140°
300
300
67
88
18
18
92
105
69
69
English
Problem
The appliance does not work.
Cause
No voltage.
Faulty cable or mains switch.
Remedy
Make sure there is voltage.
Contact the service centre.
Problem
When the thermostat reaches the set temperature, the boiler
does not come on.
Cause
No diesel.
Clogged diesel filters.
Remedy
Check the level of diesel in the fuel tank. Check the state of
cleanliness of the fuel intake circuit (presence of water). Replace
the circuit filter.
Problem
Water not hot enough.
Cause
Thermostat calibration.
Clogged filters.
Boiler coil blocked with scale.
Remedy
Check.
Clean diesel filters.
Contact the service centre.
Problem
Excessive smoking from flue.
Cause
No diesel.
Incorrect fuel.
Fuel contaminated with impurities or water.
Remedy
Fill diesel tank.
Clean diesel filters. Contact authorised service centre.
Empty the tank and clean thoroughly. Clean the various diesel
filters.
- 13 -
TROUBLESHOOTING