Status
Keys
1 key
10-digit module serial number needed to create the Alarm.com customer account.
2 key
Module firmware version (e.g., 181a).
Initiate communication test.
3 key
Important: This test is required to correctly complete the installation.
4 key
Use only when instructed by Alarm.com Technical Support.
Wireless signal strength level and module status or error, if any. The panel will display the signal level in
5 key
bars (0 to 5) and as a numerical value (0 to 31) followed by the connection mode (HSPA).
Battery voltage as read by the module, to two decimal places, and the AC power status. (e.g., Battery:
6 key
6.79v, AC Power OK).
7 key
Use only when instructed by Alarm.com Technical Support.
HSPA frequency used by the module: "High" = 900MHz, 2100MHz; "Low" = 850 MHz. The panel will specify
8 key
either "3G" or "2G" depending on your coverage, but will always attempt to go to 3G coverage.
Troubleshooting LEDs
Status LEDs indicate network and module status. The following figure shows the location of the status LEDs
on the HSPA module.
Status LEDs
LED Functions
LED
Error LED. Flashes 1 to 8 times in an 8-second interval to indicate specific error. See section "LED L1 (red)" for
L1
errors and common fixes.
Panel Communication and Z-Wave status messages. Flashes every time the module communicates with the
L2
panel and flashes in patterns to indicate Z-Wave status.
Description
L1 L2 L3 L4 L5
Function