Descargar Imprimir esta página

Hotpoint Ariston PK 644D GH X/HA LPG Manual De Instrucciones página 26

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
Connecting a flexible jointless stainless steel pipe to a
GB
threaded attachment
The gas supply pipe fitting is a threaded 1/2 gas cylindrical
male attachment.
These pipes must be installed so that they are never longer
than 2000 mm when fully extended. Once connection has
been carried out, make sure that the flexible metal pipe
does not touch any moving parts and is not compressed.
! Only use pipes and seals that comply with current national
regulations.
Checking the tightness of the connection
! When the installation process is complete, check the pipe
fittings for leaks using a soapy solution. Never use a flame.
Adapting to G30 gas
! This procedure must be performed by a qualified
technician authorised by the manufacturer.
! Once this procedure is finished, replace the old rating
sticker with one indicating the new type of gas used. Stickers
are available from any of our Service Centres.
Burner and nozzle specifications
Table 1
Burner
Fast (R)
Semi Fast (S)
Auxiliary (A)
Supply pressures
*
At 15°C and 1013,25 mbar-dry gas
**
Propane
***
Butane
S
S
A
PK 644 D GH X/HA LPG
PKQ 644 D GH /HA LPG
26
Diameter
Thermal Power
(mm)
kW (p.c.s.*)
Nomin.
Reduc.
157
2.60
1.00
132
1.75
0.80
110
0.90
0.50
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
P.C.S. = 50.37 MJ/Kg
P.C.S. = 49.47 MJ/Kg
S
R
R
A
PK 755 D GH X/HA LPG
PKQ 755 D GH /HA LPG
! Should the gas pressure used be different (or vary slightly)
from the recommended pressure, a suitable pressure
regulator must be fitted to the inlet pipe (in order to comply
with current national regulations).
DATA PLATE
Electrical
see data plate
connections
This appliance conforms to the following
European Economic Community directives:
- 2006/95/EEC dated 12/12/06 (Low
Voltage) and subsequent amendments
- 2004/108/EEC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 2009/142/EEC dated 30/11/09 (Gas) and
subsequent amendments.
- 2012/19/EC and subsequent
amendments.
Liquid Gas
Adjusting the
G31**
burner's primary
Nozzle
Flow*
By-pass
1/100
1/100
g/h
(mm)
(mm)
52
80
186
45
64
125
35
48
64
37
25
44
S
A
Liquid Gas
G30***
burner's primary
air G31
Nozzle
Flow*
1/100
g/h
(mm)
(mm)
3,70
80
189
2,60
64
127
2,20
48
65
28-30
25
35
Adjusting the
air G31
(mm)
7,10
4,00
3,50

Publicidad

loading

Este manual también es adecuado para: