1. TURNING OFF THE ELECTRICITY
Verify the wall switch is in the OFF position.
Turn off power at the circuit breaker that supplies power to the outlet box you are working on.
For screw-in type fuses unscrew the fuse that supplies power to the outlet box you are working on.
2A. INSTALLING USING THE INCLUDED WALL/EAVE MOUNTING PLATE AND COVER (OPTION 1)
For Wall /Eave mounting on standard recessed junction box
Place the sealing gasket (DD) on the knuckle stem and thread wires through the hole of the wall/eave mounting base plate (C), being careful
not to pinch the wires. (Fig. 1)
Place the fixture head (A) in the required orientation with the plate. Place the lock washer (FF) on the knuckle threaded stem and tighten the
butterfly nut (EE). (Fig. 2)
NOTE: The fixture comes with the knuckle stem and the wall/eave mounting base plate (C) is in the box.
2B. INSTALLING WITH THE SWIVEL KNUCKLE MOUNT
FOR MOUNTING TO DOMED JUNCTION BOX COVER PLATE (SOLD SEPARATELY) OR LANDSCAPE POST (SOLD SEPARATELY)
Ground and Wall/Eave Mounting
Place the sealing gasket (DD) on the knuckle mount stem (B).
Thread wires through the hole in the domed junction box cover plate or landscape post.
Screw the threaded knuckle mount (B) into the domed plate or landscape post and, if the hole is not threaded, use the lock washer (FF) and
butterfly nut (EE) to tighten the fixture into place.
Rotate the knob bolt G to loosen the screw bolt in the center of the knuckle mount stem (B) and select the desired angle. Tighten the screw
bolt to secure into place.
NOTE: The fixture comes with the 1/2 in.threaded NPS swivel knuckle mount (B) and is compatible with standard domed junction box cover plates or
landscape posts.
2A
DD
C
A
(Fig. 1)
3. ATTACHING THE MOUNTING PLATE TO JUNCTION BOX
ONLY APPLICABLE FOR WALL/EAVE MOUNT IF USING THE BASE PLATE
Remove the universal junction box mounting plate (D) from the back of the fixture by loosening the bolts
(E) using the allen key (CC). (Fig.1)
Align the holes of the junction box mounting plate (D) with the notch downwards (or furthest from the
wall if eave mounted) with the junction box on the wall and attach the junction box mounting plate (D)
on the junction box by using the two #8 screws (AA). (Fig. 2)
IMPORTANT: Only unscrew the hex plate bolts (E) far enough to remove
the mounting plate (D). Do not fully remove the hex plate bolts (E).
NOTICE: For surface mounting, use suitable bolts or fasteners for the mounting surface.
LED Slim Flood & Wall light Instructions
WARNING: Risk of electric shock. Disconnect power
at fuse or circuit breaker before installing or servicing.
A
FF
EE
(Fig. 2)
www.cooperlighting.com
2B
C
B
Domed junction box
(Fig. 3)
cover plate
IL51880222
1
B
DD
Landscape post
3
D
E
CC
(Fig. 1)
D
AA
(Fig. 2)
3