AIR SUPPLY AND CONNECTION HAZARDS:
• Air under pressure can cause several injury!
• Always shut off air supply, drain hose of air pressure and disconnect tool from air supply, when
not in use, before changing accessories or maintenance.
• Never put direct air at yourself or anyone else.
• Whipping hoses can cause serious injury. Always check for damaged or loose hoses and fittings.
• Do not exceed maximum air pressure according on the name plate respectively 6.5 bar.
• Do not use quick disconnect couplings directly at the tool. See instructions for correct set-up !
FOR ADDITIONAL SAFETY INFORMATION CONSULT:
• Your employer, union and/or trade association.
• Council of the European communities and/or local codes
• ,,Safety requirements for hand-held non-electric Power Tools", available from: European
committee for standardization, Rue de Stassart 36. 1050 BRÜSSEL, BELGIEN.
http://www.cen.eu/cenorm/homepage.htm
MAINTENANCE:
• Damaged or worn out parts should be replaced only by licensed original parts. Get in contact with
your dealer or a authorized service station for support. Using unlicensed parts male functions could occur followed by pos-
sible hurts of health.
• Check the tool regularly to recognize cracks, unusual clearance, mismatch and to check the rotary parts for proper opera-
tion.
• Recognizing a abnormality the unit needs to be provided to a authorized service station before using it again. Please con-
sider that many accidents are cause by insufficient maintenance.
TOOL APPLICATIONS:
• Pulse spray pneumatic cleaning gun: To clean automobiles
YOU MUST OBSERVE THE FOLLOWING POINTS IN THE INTEREST OF YOUR OWN SAFETY!!!
SAFETY INSTRUCTIONS:
• The B020 causes considerable noise pressure. Please wear hearing protection in order to avoid noise which can be dam-
aging to your health.
• When working with the B020, small parts may be whirled into the air: Wear protective goggles to prevent eye injuries.
• Only use the B020 in ventilated spaces.
• Never operate the B020 with more than 6.5 bar.
• Never point the B020 towards the face or body.
• Keep the B020 out of the reach of children.
We recommend you never clean any safety-related components, e.g. safety belts, electrical
or electronic modules, with the B020.
SPECIAL INSTRUCTIONS:
The written and spoken information and recommendations which we provide to support the purchase/user, are the result
of previous experience and the latest findings. Because of the manifold possibilities for use and processing conditions, this
information is without obligation and do not constitute a contractual legal relationship or any supplementary obligations of
the sales contract. In any event, the purchaser holds responsibility for checking suitability for the intended use himself.
Always read the safety warnings for cleaning liquids and contact the manufacturer in case of doubt. Our liability and
repsonsibility is based exclusively on our general terms and conditions of business and are not expanded on by either this
information or the technical advice of our technical field staff.
OPERATING INSTRUCTIONS:
1. Remove loose soiling from the surface you wish to clean (brush or vacuum clean)
2. Important: Hold the cleaning spout at a distance of only 1-3 cm from the surface you are
cleaning.
3. Press the "trigger" all the way; move the B020 slowly with circular motions over the
surface you are cleaning.
REQUIRED AIR RATE
To perform to its full potential, the B020 requires a constant air pressure of 4,5 - 6,5 bar.