12. Brewing Time Setting Function
brewing time according to your demand.
1. To adjust the single cup amount, press and hold the "single-cup button" for 3
seconds,the machine beep 3 times and start to brewing.
2. To adjust the double cup amount, press and hold the "double-cups button" for 3
seconds,the machine beep 3 times and start to brewing.
When the coffee in the cup reaches the required set amount, press the "Single-cup
or double-cup coffee button" to stop brewing. Machine beep three times, indicating
that amount has been set and the next coffee discharging time will follow the last set
value.
NOTE: Coffee brewing time is set between 8-60 seconds; otherwise, the setting is
failed.
13. Coffee temperature selection function
1. Press the "On/Off button", the machine starts to preheat automatically. Once the
main menu of program settings.
Single-cup light on = Low temperature coffee brewing mode
Double cup light on = Middle temperature coffee brewing mode (Default mode)
Steam light on = High temperature coffee brewing mode
4. Press the corresponding button above according to the temperature mode you,
for 3 times,the temperature set successfully and return to brewing coffee state.
NOTE: If there is no any operation within 15S, machine will exit program setting and