High Altitude
Notice
The specified gas burner ratings typically apply to
elevations up to 2000 feet. For higher altitudes, the rates
may need to be reduced to achieve satisfactory operation.
A local certified gas servicer will be able to advise if a
reduction is necessary.
]_
_--
SCREWS
9.1k/10.5k
!___t-----BURNER
BASE
BURNER CHOKE_
t@:-L-
(CHAMFER
""C-_
B. INVERT CAP IN APPLIANCE
PRESSURE
REGULATOR
(See figure 12)
With the appliance installed, the appliance regulator
should be located as shown in figure 3 or 4.
CONVERSION
OF APPLIANCE
APPLY D OWNWARD
PRESSURE
REGULATOR
FINER P RESSURE
ATDISC EDGES TD
FIGURE 12
ORIFICE HOLDER
OR, F,OE
SPUO
#
FIGURE
'0
C. LOW FLAME ADJUSTMENT
(See figure 13)
This appliance is shipped from the factory with low and
high flame settings adjusted for use with natural gas.
To set for use with LP proceed as follows:
1. Remove control knob from valve stem.
SCREWS
ORIFICE SPU D__S
O RiFSi:U_III
DER
Step 7:
JGC8430 - 30" Unit - Place the 14k burner choke
into the right front orifice holder (see figure 11 ).
JGC8536 - 36" Unit - Place 14k burner choke into
center orifice holder (see figure 11).
Step 8: Replace burner base, caps, and grates.
Tighten (T-15) 6-lobe screws (do not cross thread) to
25-30 in Ibs.
Step 9: Save the orifices removed from the appliance
for future use.
Step 10: Sign and apply labels supplied in orifice kit to
bottom of unit.
2. Carefully remove rubber grommet.
3. Locate the valve adjustment screw. See figure 13.
4. Insert a slender, thin-blade screwdriver into knob
hole and engage blade with slot in adjusting screw.
5. Turn the adjusting screw clockwise until tight (5-7
in-lbs max.). Do not over tighten.
6. Replace rubber grommet and control knob.
7. Repeat for remaining burners.
VIEW
THROUGH
KNOB
HOLE
/
SCREW
KNOB HOLE
(KNOB & GROMMET
REMOVED)
ART#9215H6_O